Alarm messages

SHDSL Network Termination Unit software download complete

...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
NTUcSWDC
The download of a new software image to the NTU has completed
successfully.
Equipment
sdsl
Deferred
Reported
When the download of a new software image has completed successfully, a
"Software download complete" (SWDC) notification is generated as a reminder
that a reset is required to activate the new software image.
Reset the NTU in order to activate the new software image.
Alcatel-Lucent - Proprietary
See notice on first page
1-149