FIG. 6.3a
1) POP SUPPORT BOARD
2) TRUSS SCREW (3), chrome
(P. 15)
[4] INSERTING THE MANAGEMENT CHIP AND MUSHIKING CARDS
While consulting section 7, "MANAGEMENT CHIP AND MUSHIKING CARDS", insert the
Management Chip into the Management Chip reader/writer, and load the cards into the card dispenser.
PHOTO 6.4
1) MANAGEMENT CHIP
2) MANAGEMENT CHIP READER/WRITER
(P. 18)
[5] POWERING ON
IMPORTANT
(STOP)
This machine cannot be powered on unless both the AC unit on the back of the
cabinet and the power switch in the maintenance switch section on the inside of
the service door are both turned on.
Turning on the AC unit main switch and the maintenance switch will power on the machine. When
powering on the machine, the system start-up screen will be displayed, and an advertisement screen will be
shown afterwards. On this machine, the number of credits will be saved even after shutting off the power.
If credits allowing further play remain in the machine when powered off, a card will be dispensed and a
game will begin when the machine is restarted.
・In the event that there are no cards loaded into the card dispenser, a "CARD ERROR" message screen
will be displayed. In such a case, turn off the machine, load cards, and turn it on again.
・In the maintenance switch section of the service door, use the audio volume adjuster to regulate the
volume. Also, the choice of whether or not to play sound during the advertisement screen can be selected in
the TEST MODE settings.