Table 5-1. POST Error Codes and Messages (continued)
Error Code and Message
0231
Shadow RAM Failed
at offset:
0232
Extended RAM
Failed at address
line:
0250
System Battery is
Dead - Replace and
Run SETUP
0251
System CMOS
Checksum Bad -
Default
Configuration Used
0252
Password
Checksum Error
0260
System Timer Error
0270
Real Time Clock
Error
0271
Check date and time
setting
0280
Boot Error
0281
Memory Size Error
02B0
Diskette drive A
error
02B1
Diskette drive B
error
02B2
Incorrect Drive A
type - run SETUP
02D0
System Cache Error Cache disabled
02D1
System Memory
Error
02F4
EISA CMOS Error
Table 5-1. POST Error Codes and Messages (continued)
5-14 Problem Solving
Description
Shadow RAM error
Extended RAM error
No battery is available for the
system.
Checksum of system CMOS is
not correct.
Password Checksum bad –
Password cleared
System timer error
Real-time clock error
Real-time clock is set incorrectly.
Previous boot incomplete –
Default configuration used.
Memory Size found by POST
deferred from EISA CMOS.
Floppy disk A error
Floppy disk B error
The type of drive A is incorrect.
System Memory exceeds the
CPU's caching limit.
EISA CMOS not write able.
Action
Contact your service representative.
Contact your service representative.
Contact your service representative to
replace the battery on the system board.
(After battery is replaced, start the SETUP
utility to set required values again.)
The default values were set. Start the
SETUP utility to set required values again. If
the same error still occurs, call your service
representative.
The password has just been cleared. Start
SETUP to provide the setting again.
Contact your service representative to
replace the system board.
Replace the system board. Contact your
service representative to replace the system
board.
Start the SETUP utility and select [Main] →
[System Time] → [System Date] to set the
correct time. If the same error reoccurs,
contact your service representative to
replace the system board.
Contact your service representative.
Contact your service representative.
Start the SETUP utility and select [Main] →
[Diskette A] to set the required value again.
Check if the floppy drive cable is correctly
connected. If the error persists, contact your
service representative to replace the system
board or floppy disk drive.
Not Applicable as this server does not have
a Floppy Disk B.
Start the SETUP utility to set required values
again. If the error persists, contact your
service representative to replace the system
board.
The cache cannot be used. Contact your
service representative.
Contact your service representative.
Contact your service representative.