Table 3-2
9903-UDX-ADDA Function Menu List — continued
Ancillary Data Proc Controls
Eight individual Ancillary Data Processors (ADPs) provide for insertion, extraction, or bridging ancillary data to and from the card
program video SDI stream.
Mode controls select the type of ANC
processing:
• Bridge extracts ANC from the deserialized
input video and re-inserts in the output
video, thereby allowing specialized ANC
packets to be retained after the scaler and
passed on the card processed output (for
example, preserving special payloads
such as STCE 104 for a format-converted
output)
• Insert and Extract modes respectively
allow insertion to the output stream or
extraction from the input stream between
external interfaces
In the example above, ADP Proc 1 is set to extract ATC timecode at DID60
IP), status is displayed as shown below.
Note: DashBoard versions 4.1 and earlier display DID and SDID numbers in decimal; newer DashBoard versions display DID and SDID numbers in
hexadecimal. Hexadecimal notation is denoted by the "0x" preceding the value.
9903UDXADDA-OM (V1.5)
9903-UDX-ADDA Function Menu List and Descriptions
(Option +ANC) Provides controls for VANC/HANC
ancillary data de-embedding and embedding to and
from program video stream. Data can be extracted and
inserted within the card, bypassing the scaler (Bridge
mode), or inserted and/or extracted to and from
external interfaces via serial or IP interfaces.
Interface controls select either card IP or
serial data (COM 1) interface where Mode is
set to insertion or extraction
Note: COM1 is available for ADP Proc 1
only; all other ADPs use IP only for external
import/export insertion/extraction.
DID and SDID controls select the
desired packet to be handled by
the corresponding ANC Data
Processor
h
When set to extract to COM interface, displays rate and dropped data (if any)
When set to extract to IP interface, displays rate and total amount transferred
9903-UDX-ADDA PRODUCT MANUAL
Line Number controls select
the VANC location of packet
insertion/extraction
/ SDID 60
. Depending on the interface used to carry the extraction (COM or
h
Insertion controls allow
special insertions in HANC
or the C-channel, as well as
removal of incoming packets