Renishaw RMP400 Installation Manual page 36

High accuracy radio machine probe
Hide thumbs Also See for RMP400:
Table of Contents

Advertisement

RMP400 installation guide
Master reset function
RMP400 features a master reset function to assist
user's who have mistakenly changed the probe
settings into an unintended state.
The application of the master reset function will
clear all current probe settings and return the
4.8
probe to default settings.
The default settings are as follows:
Radio switch-on
Radio switch-off
Auto-reset on, Enhanced trigger filter on 8 ms
Hibernation mode on 30 s
Multiple probe mode off
The default settings may not be representative of
the required probe settings. Further configuration
of RMP400 may subsequently be necessary to
achieve the required probe settings.
1.
Probe is in the Trigger Logic menu.
Ensure that the stylus is no longer deflected.
2.
Whilst the status LEDs are flashing yellow to confirm that
a master reset is required, release the stylus and then
hold the stylus deflected again until the eight yellow flash
sequence has ended.
Previous settings have been cleared.
The probe now has default settings.
Draft 5 16/04/18
To reset the probe
1.
First enter into the Trigger Logic™ menu and
ensure that the stylus is no longer deflected.
2.
From within the Trigger Logic menu, hold the
stylus deflected for 20 seconds. After this
the status LEDs will proceed to flash yellow
eight times. A confirmation for master reset
is required, if nothing is done the probe will
timeout.
To confirm that a master reset is required,
release the stylus and then hold the stylus
deflected again until the eight yellow flash
sequence has ended. This action will clear
all probe settings and return the probe to
default settings. Following an LED check the
RMP400 will then go back into Trigger Logic
and will display "Switch-on method".
3.
Further configuration using Trigger Logic may
be necessary to achieve the required probe
settings.
Deflect the stylus for 20 seconds until the
status LEDs start to flash yellow eight times.
System status LED