Rmp400 - Rmi Partnership - Renishaw RMP400 Installation Manual

High accuracy radio machine probe
Hide thumbs Also See for RMP400:
Table of Contents

Advertisement

RMP400 – RMI partnership
System set-up is achieved using Trigger Logic
and powering the RMI. Partnering is only required
during initial system set-up. Further partnering
will be required if either the RMP400 or RMI
is changed, or if a system is reconfigured for
multiple probes (multiple probe mode).
4.10
NOTE: Please refer to the
installation guide RMI radio
machine interface (Renishaw part
no. H-4113-8554) when partnering
the RMP400.
Acquisition mode
Acquisition mode off
Switch the RMI on
RMI in acquisition mode
Draft 5 16/04/18
Partnering will not be lost by reconfiguring the
probe settings or when changing batteries, except
where multiple probe mode is selected. Partnering
can take place anywhere within the operating
envelope.
In configuration mode, configure the probe
settings as required until you reach the
"Acquisition mode" menu, which defaults to
"Acquisition mode off".
SIGNAL LED
Deflect the stylus to select "Acquisition
mode on". Ensure this is done within
8 seconds of the RMI signal LED
flashing green.
New partner RMP acquired
The probe is now in standby
and the system is ready for use.
> 20 s
SIGNAL LED

Advertisement

Table of Contents
loading

Table of Contents