RMP400 – RMI-Q partnership
System set-up is achieved by using Trigger Logic
and powering on the RMI-Q or applying ReniKey.
Partnering is required during initial system set-up.
Further partnering will be required if either the
RMP400 or RMI-Q is changed.
Partnering will not be lost by reconfiguring
the probe settings or changing the batteries.
Partnering can take place anywhere within the
operating envelope.
SYSTEM STATUS LED
RMI-Q in acquisition mode
with empty probe location
NOTE: Please refer to the
installation guide RMI-Q radio
machine interface (Renishaw part
no. H-5687-8504) when partnering
up to four RMPs.
Draft 5 16/04/18
An RMP400 that is partnered with the RMI-Q
but then used with another system will need to
be repartnered before being used again with the
RMI-Q.
In configuration mode, configure the probe
settings as required until you reach the
"Acquisition mode" menu, which defaults to
"Acquisition mode off".
Acquisition mode
Acquisition mode off
Switch the RMI-Q on
or
RMI-Q in acquisition mode
Deflect the stylus to select "Acquisition
mode on". Ensure this is done within 60
seconds of the RMI-Q system status
LED flashing green.
SYSTEM STATUS LED
SYSTEM STATUS LED
New partner RMP acquired
Displayed for 5 seconds
> 20 s
SYSTEM STATUS LED
with full probe location
Acquisition pending
SYSTEM STATUS LED
or
RMP cleared from location
The probe is now in standby
and the system is ready for use.