Changing The Probe Settings - Renishaw RMP400 Installation Manual

High accuracy radio machine probe
Hide thumbs Also See for RMP400:
Table of Contents

Advertisement

RMP400 installation guide

Changing the probe settings

Insert the batteries or, if they have already been
installed, remove them for five seconds and then
refit them.
Following the LED check, immediately deflect the
stylus and hold it deflected until eight red flashes
4.6
have been observed (if the battery power is low,
each red flash will be followed by a blue flash).
Keep the stylus deflected until the "Switch-on
method" setting is displayed, then release it.
CAUTION: Do not remove the batteries whilst
in configuration mode. To exit, leave the stylus
untouched for more than 20 seconds.
Key to the symbols
LED short flash
LED long flash
Deflect the stylus for less than 4 seconds
to move to the next menu option.
Deflect the stylus for more than
4 seconds to move to the next menu.
To exit, leave the stylus untouched for
more than 120 seconds.
To exit, leave the stylus untouched for
more than 20 seconds.
Radio off or
Auto reset off
Trigger filter
on 8 ms
Switch-on method
(omitted if "multiple probe mode" was selected)
Radio on
Switch-off method
Short
Spin off
timeout
12 s
Enhanced trigger filter setting and auto-reset facility
Auto reset off
Auto reset on
Trigger filter
on 16 ms
Draft 5 16/04/18
1
LED check
Probe status (triggered)
Battery good
Spin on
Medium
Long
timeout
timeout
33 s
134 s
Auto reset on
Trigger filter
Trigger filter
on 8 ms
on 16 ms
2
> 5 s
3
Battery low
or
Auto reset off
Trigger filter
off