Renishaw RMP400 Installation Manual page 13

High accuracy radio machine probe
Hide thumbs Also See for RMP400:
Table of Contents

Advertisement

RMP400 switch-on method
Switch-on options are configurable
Radio on
Radio switch on is commanded by
machine input.
Spin on
Spin at 500 rev/min for one second
minimum.
NOTES:
In "radio on" mode, the switch-on time is user
selectable "fast" or "standard" when using
RMI-Q (selection is made in RMI-Q). Otherwise
1.7 seconds.
For more information on the user selectable
switch-on time when operating with RMI-Q, please
refer to the installation guide RMI-Q radio machine
interface (Renishaw part no. H-5687-8504).
In "radio on" mode, the switch-on time assumes
a good radio communication link. In a poor RF
environment this may rise to a maximum of
3.0 seconds.
Draft 5 16/04/18
RMP400 switch-off method
Switch-off options are configurable
Radio off
Radio switch off is commanded by
machine input. A timer automatically
switches the probe off 90 minutes
after the last trigger if it is not turned
off by machine input.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
Spin off
Spin at 500 rev/min for one second
minimum. A timer automatically
switches the probe off 90 minutes
after the last trigger if it is not spun.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
In "spin on" mode, the one second starts from
the moment the spindle reaches 500 rev/min.
The RMP400 must be on for a minimum of
one second before being switched off.
Probe ready time
1.7 seconds
maximum.
2.5 seconds. (The
probe must be
stationary for 2.5
seconds minimum
after it has stopped
spinning.)
2.3

Advertisement

Table of Contents
loading