Aci Interface - Renishaw ATOM Installation Manual

Linear encoder systems
Hide thumbs Also See for ATOM:
Table of Contents

Advertisement

System connection:

ACi interface

FPC variant
FPC input
connector
PCB
FPC
cable
Ensure that the FPC cable being used has the following specifications:
16 core
u
Conductor pitch 0.5 mm
u
Minimum exposed conductor strip length 1.5 mm
u
Maximum exposed conductor strip length 2.5 mm (to ensure isolation from the body)
u
Contact your local Renishaw representative for more information of the FPC design requirements.
Shielding
For optimum performance:
Ensure 100% shielding
u
Ground the mounting brackets, readhead and FPC cable clamp
u
u
Ensure continuity of all shields
Maximise the distance between the encoder and motor cables
u
Provide appropriate strain relief at the readhead and interface
u
The ACi should be contained within a shielded enclosure
u
Mounting
ACi can be mounted to customers' system using 2 off M3 screws or 2 off M2.5 screws for through mounting.
Output
The output connector is a 10 way JST, GH crimp connector with 1.25 mm pitch.
It is suitable for cable size 26 to 30 AWG. See page 29 for pin-out information.
Connection
For information on inserting and removing the FPC cable to the ACi and readhead see page 12.
Approved ESD precautions must be followed at
all times during readhead electrical connection.
The FPC cable must be connected to the readhead before fitting the lid.
The lid is secured by the readhead mounting screws.
ATOM
linear installation guide
FPC input
connector
Pin 1
Pin 1
2 mounting holes
M3 through
Cable variant
JST output
connector
Cable
interboard
connector
PCB
*
Ensure suitable clamping to retain interboard connector on ACi.
Shielding
For optimum performance:
Ensure 100% shielding
u
Ground the mounting brackets
u
Use a metal clamp around the cable ferrule to ground the readhead cable
u
Ensure continuity of all shields
u
Maximise the distance between the encoder and motor cables
u
Provide appropriate strain relief at the readhead and interface
u
u
The ACi should be contained within a shielded enclosure
Ensure suitable clamping to retain interboard connector to the mating connector
u
Mounting
ACi can be mounted to customers' system using 2 off M3 screws or 2 off M2.5 screws for through mounting.
Output
The output connector is a 10 way JST, GH crimp connector with 1.25 mm pitch.
It is suitable for cable size 26 to 30 AWG. See page 30 for pin-out information.
Approved ESD precautions must be followed at
all times during readhead electrical connection.
Ferrule
JST output
connector
2 mounting holes
M3 through
Cable
interboard
*
connector
13

Advertisement

Table of Contents