Electrical Connections - Renishaw ATOM Installation Manual

Linear encoder systems
Hide thumbs Also See for ATOM:
Table of Contents

Advertisement

Electrical connections

Grounding and shielding
FPC readhead
FPC cable
Shield
(recommended)
For more information on FPC contact your local Renishaw representative.
Cable readhead
Shield
IMPORTANT: The shield should be connected to the machine earth (Field Ground).
NOTE: Maximum cable length between interface and customer electronics is
25 m for ACi and Ri and 50 m for Ti.
(Maximum length for Ti with 40 or 50 MHz clocked output is 25 m).
ATOM
linear installation guide
ACi/customer
electronics
5 V
Output
signals
0 V
Connector/
interface
Recommended signal termination
Digital outputs
Interface
A B Z E+
A B Z E-
Standard RS422A line receiver circuitry.
Capacitors recommended for improved noise immunity.
Customer
electronics
Remote CAL operation
5 V
CAL
Output
signals
0 V
0 V
0 V
Customer
220 pF
electronics
Cable Z
= 120R
120R
0
220 pF
0 V
Remote CAL operation is possible
via the CAL pin.
For applications where no interface is used,
remote CAL operation is essential.
Analogue outputs
V
V
V
+
0
1
2
120R
V
V
V
-
0
1
2
37

Advertisement

Table of Contents
loading

Table of Contents