6. LW2 Programmers' Reference
6.2.11. Query Health Status
Description: Queries health status. The response depends on the frame type.
Format
Command {ST}
Response (ST●<DESC>)CrLf
Explanation: Internal voltages, temperature and fan speeds shown.
6.2.12. Restore Factory Default Settings
Description: Settings can be reset to factory default values as follows:
Format
Command {FACTORY=ALL}
Response (FACTORY ALL...)CrLf
Explanation: All settings and parameters are reset to factory default, see the table in
section.
6.3. Port and Crosspoint Settings
6.3.1. Switch One Input to One Output
Description: Switch input <in> to output <out>.
Format
Command {<in>@<out>}
Response (O<out²>●I<in²>)CrLf
Explanation: Input 1 is switched to output 2.
ATTENTION! The response of this command does not show if the output is muted. To check the mute
status a separate query has to be used like {VC}. See
achieve multiple switches executed together, see
6.3.2. Switch One Input to All Output
Description: Switch input <in> to all outputs.
Format
Command {<in>@O}
Response (I<in²>●ALL)CrLf
Explanation: Input 2 is switched to all outputs.
Example
→ {st}
← (ST CPU 5.14V 3.38V 57.29C 63.30C 63.00C 51.05C
62.74C 63.25C 58.44C)CrLf
Example
→ {factory=all}
← (FACTORY ALL...)CrLf
Factory Default Settings
Example
→ {2@1}
← (O01 I02)CrLf
View Connection State on the Output
Batch Switch Outputs
section.
Example
→ {2@O}
← (I02 ALL)
MMX8x4-HT series – User's Manual
6.3.3. Mute Specified Output
Description: Mute output <out>. The output signal is turned off.
Command {#<out>}
Response (1MT<out²>)CrLf
Explanation: O1 port is muted.
ATTENTION! Muting does not change the crosspoint's state but disables the output itself. This way the
last connection can be easily restored with an unmute command. Switching a muted output does not
unmute the output.
6.3.4. Unmute Specified Output
Description: Unmute output <out>.
Command {+<out>}
Response (0MT<out²>)CrLf
Explanation: O1 port is unmuted.
INFO: Unmuting an output makes the previous connection active as the crosspoint's state has not been
changed with the muting command, only the output was disabled.
6.3.5. Lock the Output
Description: Lock output <out>. Output's state cannot be changed until unlocking
Command {#><out>}
Response (1LO<out²>)CrLf
section. To
Explanation: O1 port is locked.
6.3.6. Unlock the Output
Description: Unlock output <out>. The connection on output can be changed.
Command {+<<out>}
Response (0LO<out²>)CrLf
Explanation: Output 1 is unlocked.
INFO: The device issues the above response regardless of the previous state of the output (either it was
locked or unlocked).
Format
→ {#01}
← (1MT01)CrLf
Format
→ {+01}
← (0MT01)CrLf
Format
→ {#>01}
← (1LO01)CrLf
Format
→ {+<01}
← (0LO01)CrLf