6. LW2 Programmers' Reference
6
L W2 Programmers' Reference
Lightware MMX8x4-HT family can be controlled with external devices which
can communicate according to the extender protocol. The supported LW2
commands are described in this chapter.
LW2 Protocol Description
Ý
General LW2 Commands
Ý
Port and Crosspoint Settings
Ý
Network Configuration
Ý
GPIO Settings
Ý
Relay Settings
Ý
LW2 Commands – Quick Summary
Ý
MMX8x4-HT series – User's Manual
6.1. LW2 Protocol Description
The device accepts commands surrounded by curly brackets - { } - and responds data surrounded by round
brackets - ( ) - only if a command was successfully executed.
Format Explanation
<in>
Input number in 1 or 2 digit ASCII format (01, 5, 07, 16, etc.)
<out>
Output number in 1 or 2 digit ASCII format
<in
>
Input number in 2 digit ASCII format (01, 02, 10, 12 etc.)
2
<out²> Output number in 2 digit ASCII format (01, 02, 10, 12 etc.)
<loc>
Location number in 1, 2 or 3 digit ASCII format
<id>
id number in 1 or 2 digit ASCII format
<id²>
id number in 2 digit ASCII format
CrLf
Carriage return, Line feed (0x0D, 0x0A)
Space character (0x20)
●
→
Each command issued by the controller
←
Each response received from the router
6.2. General LW2 Commands
6.2.1. View Product Type
Description: The device responds its name.
Format
Command {I}
Response (<PRODUCT_TYPE>)CrLf
Explanation: The connected device is an MMX8x4-HT420M.
Legend: <PRODUCT_TYPE> shows type.
6.2.2. View Serial Number
Description: The device responds its 8-digit serial number.
Format
Command {s}
Response (SN:<SERIAL_N>)CrLf
Example
→ {i}
← (I:MMX8x4-HT420M)CrLf
Example
→ {s}
← (SN:00005484)CrLf
64