Closing Reports
(0511)
(Default = off) This setting determines whether or not the
panel sends a closing report to the central station (or pager)
after arming the system.
Ìi
To use this feature, the OPEN/CLOSE REPORTS
settings under the PHONES—CS PHONE 1-2
and/or PHONES—PAGER PHONE 1-3 menus
must be turned on for the specific CS Phone or
Pager Phone number.
To turn Closing Reports off or on:
With the display showing CLOSING REPORTS OFF/
ON (current setting), press
display flashes the entered setting. Press
display shows the new setting.
Recent Closings
(0512)
(Default = on) This setting determines whether or not the
panel sends a recent closing report to the central station (or
a pager) if an alarm occurs within two minutes after the exit
delay time expires. Such a report is used to identify a
possible exit fault.
To turn Recent Closings off or on:
With the display showing RECENT CLOSINGS OFF/
ON (current setting), press
display flashes the entered setting. Press
display shows the new setting.
No Activity
(0513)
(Default = off) This setting determines whether or not the
panel sends a no activity report to the central station (or
pager) if there is no system activity within a preset time
period (see TIMERS—ACTIVITY TIMEOUT).
To turn No Activity reports off or on:
With the display showing NO ACTIVITY OFF/ON
1 (off) or 2 (on). The display
(current setting), press
flashes the entered setting. Press
shows the new setting.
(Reporting—Partition 1)
1 (off) or 2 (on). The
ƒ and the
(Reporting—Partition 1)
1 (off) or 2 (on). The
ƒ and the
(Reporting—Partition 1)
ƒ and the display
Duress Option
(0514)
(Default = off) This setting determines whether or not the
system can be controlled using a programmed duress code
(see SECURITY—PARTITION 1—DURESS CODE).
ÁIG"42
Because using duress codes often results in false
alarms due to code entry errors, it is strongly
recommended not to program any duress codes.
If a duress code is absolutely necessary, their use
with an Interrogator is highly recommended to
reduce false alarms and accidental dispatches.
To turn Duress Option off or on:
With the display showing DURESS OFF/ON (current
1 (off) or 2 (on). The display flashes
setting), press
the entered setting. Press
setting.
Force Armed
(0515)
(Default = off) This setting determines whether or not the
panel reports to the central monitoring station when a user
force arms the system.
Force Armed occurs if the user presses BYPASS when
arming the system with open sensors/zones protesting.
Ìi
Auto Force Armed always reports to the central
monitoring station.
Auto Force Armed occurs if the user does not
press BYPASS when arming the system with open
sensors/zones protesting and the siren time
expires.
Ìi
For UL Listed systems, Force Armed must be
turned off.
To turn Force Armed off or on:
With the display showing FORCE ARMED OFF/ON
(current setting), press
flashes the entered setting. Press
shows the new setting.
Programming the Panel
(Reporting—Partition 1)
ƒ and display shows the new
(Reporting—Partition 1)
1 (off) or 2 (on). The display
ƒ and the display
27
Need help?
Do you have a question about the Concord Express and is the answer not in the manual?
Questions and answers