Programming the Panel
Backup
(0104-cs phone 1, 0114-cs phone 2)
(Defaults: CS Phone 1 = on, CS Phone 2 = off) This setting
determines whether or not the panel uses another
programmed central station phone number for reporting if
three initial attempts are unsuccessful.
CS PHONE 1 is backed up by CS PHONE 2, and CS
PHONE 2 is backed up by CS PHONE 1. The panel makes
up to 16 attempts (8 per phone number), alternating
between the two programmed phone numbers.
For example, if BACKUP is on and three failed reporting
attempts occur using CS PHONE 1, the panel switches to
CS PHONE 2 for three more reporting attempts. If these
attempts fail, the panel switches back to CS PHONE 1 for
five more reporting attempts and, if necessary, switches
back to CS PHONE 2 for five final attempts.
To turn Backup off or on:
With the display showing BACKUP OFF/ON (current
1 (off) or 2 (on).
setting), press
The display flashes the entered setting. Press
the display shows the new setting.
Reporting Format
(0105-cs phone 1, 0115-cs phone 2)
(Defaults: all CID) This setting determines whether the
panel uses the SIA or CID (Contact ID) reporting format
for central station communication.
To select SIA or CID Reporting Format:
With the display showing REPORTING FORMAT SIA/
CID (current setting), press
CID).
The display flashes the entered setting. Press
the display shows the new setting.
18
(Phones—CS Phone 1-2)
ƒ and
(Phones—CS Phone 1-2)
1 (for SIA) or 2 (for
ƒ and
The following describes how to program the phone settings
that appear under PAGER PHONE 1 thru 3.
Phone Number
(0120-pager 1, 0130-pager 2, 0140-pager 3)
(Default = none) This setting is used for programming a
phone number that communicates to a pager. Phone
numbers can be 1 to 24 digits long, and can include pauses
or * and # characters. To enter pauses, press
7 for one second. To enter #, press and hold
press and hold
9 for one second.
œÌi
Call-waiting services should be disabled to prevent
interruptions to panel communication to the central
monitoring station (or pager). To program a dialing
prefix that disables call-waiting, see the CALL
WAIT CANCEL setting under the menu PHONE
OPTIONS—GLOBAL.
To program a Pager Phone Number:
With the display showing PHONE NUMBER _ (or
current number), enter the desired pager phone
number including pauses.
The display flashes the entered number. Press
the display shows the new number.
To delete a Pager Phone Number:
With the display showing PHONE NUMBER (current
D .
number), press
The display shows PHONE NUMBER _.
High Level Rpts
(0121-pager 1, 0131-pager 2, 0141-pager 3)
(Default = on) When this setting is on, the panel reports to
the pager events that involve a high-level security risk,
including the following conditions:
q Fire, Police, Auxiliary, Duress, and Freeze alarms
q No Activity
q Receiver Failure (or jam)
q System Tamper (40 incorrect keystrokes or touchpad
supervisory),
q Entering or exiting Sensor Test mode
To turn High-Level Reports off or on:
With the display showing HIGH LEVEL RPTS OFF/
ON (current setting), press
The display flashes the entered setting. Press
the display shows the new setting.
(Phones—Pager Phone 1-3)
C . To enter *,
ƒ and
(Phones—Pager Phone 1-3