Programming the Panel
Auto Phone Test
(02001)
(Default = off) This setting determines if the panel sends a
phone test automatically to the central station (or a pager)
on a predetermined schedule. (Refer to the "Phone Test
Freq." and "Next Phone Test" settings found under
TIMERS—GLOBAL).
To turn Automatic Phone Test off or on:
With the display showing AUTO PHONE TEST OFF/
ON (current setting), press
The display flashes the entered setting. Press
the display shows the new setting.
Auto Test Reset
(02002)
(Default = on) This setting determines whether or not the
Auto Phone Test interval is reset after any successful report
to the central monitoring station. (Refer to the "Phone Test
Freq." and "Next Phone Test" settings found under
TIMERS—GLOBAL).
When this feature is on, the panel considers any successful
report to the central station to be a successful phone test.
Thus, any successful panel report to the central monitoring
station resets the Next Phone Test setting to the Phone Test
Freq. value. The panel only conducts an Auto Phone Test if
no other reports are made during the Phone Test Freq. time
period.
When this feature is off, an Auto Phone Test is always
conducted according to the Phone Test Freq. setting, even if
the panel makes other reports to the central monitoring
station during that time period.
œÌi
PHONE TEST FREQ must be set to 2 or higher for
this feature to work.
To turn Auto Test Reset off or on:
With the display showing AUTO TEST RESET OFF/
ON (current setting), press
The display flashes the entered setting. Press
the display shows the new setting.
Comm Failure
(02003)
(Default = on) When this setting is on, the panel activates
trouble beeps to alert users on the premises that
communication to the central station has failed. Failure
notification occurs after the third unsuccessful reporting
attempt to the central station (or pager).
œÌi
For UL Listed systems, Comm Failure must be
turned on.
To turn Communication Failure notification off
or on:
With the display showing COMM FAILURE OFF/ON
(current setting), press
The display flashes the entered setting. Press
the display shows the new setting.
20
(Phone Options—Global)
1 (off) or 2 (on).
ƒ and
(Phone Options—Global)
1 (off) or 2 (on).
ƒ and
(Phone Options—Global)
1 (off) or 2 (on).
ƒ and
DTMF Dialing
(02004)
(Default = on) This setting determines whether the panel
uses DTMF tones (on) or pulse (off) for dialing
programmed phone numbers.
To turn DTMF Dialing off or on:
With the display showing DTMF DIALING OFF/ON
1 (off) or 2 (on).
(current setting), press
The display flashes the entered setting. Press
the display shows the new setting.
Dialer Abort
(02005)
(Default = on) This setting determines whether or not users
can stop the first dialing attempt of the panel (within the
Dialer Abort Delay time setting) to report to the central
station. When this feature is on, alarm reports from sensors
in groups 00-20, 34, and 35 can be aborted by entering 1 +
CODE within the Dialer Abort Delay time setting
(defaulted to 30 seconds). Cancel and restoral reports from
these sensor groups are also aborted if the related alarm
report was aborted. Other reports that can be aborted
include System Alarm Tamper/Cancel, No Activity Alarm/
Cancel, Touchpad Police and Auxiliary Panic/Cancel,
Recent Closing, and Two Trip Error. Fire alarm reports to
the central station cannot be aborted.
To turn Dialer Abort off or on:
With the display showing DIALER ABORT OFF/ON
1 (off) or 2 (on).
(current setting), press
The display flashes the entered setting. Press
the display shows the new setting.
Dial Abort Delay
(02006)
(Default = 30 seconds) This setting determines how much
time (15-120 seconds) the user has to enter the disarm
command in order to prevent the panel from reporting to
the central monitoring station.
To change the Dial Abort Delay:
With the display showing DIAL ABORT DELAY nn
(current setting), enter the desired time (15-120
seconds).
The display flashes the entered setting. Press
the display shows the new setting.
(Phone Options—Global)
ƒ and
(Phone Options—Global)
ƒ and
(Phone Options—Global)
ƒ and