No.
Description
2809
AR: Start-signal monitoring time
expired (AR T-Start Exp)
2810
AR: Maximum dead time expired
(AR TdeadMax Exp)
2818
AR: Evolving fault recognition
(AR evolving Flt)
2820
AR is set to operate after 1p trip
only (AR Program1pole)
2821
AR dead time after evolving fault
(AR Td. evol.Flt)
2839
AR dead time after 1pole trip
running (AR Tdead 1pTrip)
2840
AR dead time after 3pole trip
running (AR Tdead 3pTrip)
2841
AR dead time after 1phase fault
running (AR Tdead 1pFlt)
2842
AR dead time after 2phase fault
running (AR Tdead 2pFlt)
2843
AR dead time after 3phase fault
running (AR Tdead 3pFlt)
2844
AR 1st cycle running (AR 1stCyc.
run.)
2845
AR 2nd cycle running (AR
2ndCyc. run.)
2846
AR 3rd cycle running (AR 3rdCyc.
run.)
2847
AR 4th or higher cycle running
(AR 4thCyc. run.)
2848
AR cycle is running in ADT mode
(AR ADT run.)
2851
AR: Close command (AR CLOSE
Cmd.)
2852
AR: Close command after 1pole,
1st cycle (AR Close1.Cyc1p)
2853
AR: Close command after 3pole,
1st cycle (AR Close1.Cyc3p)
2854
AR: Close command 2nd cycle
(and higher) (AR Close 2.Cyc)
2857
AR: RDT Close command after
TDEADxTRIP (AR CLOSE RDT
TD)
2861
AR: Reclaim time is running (AR
T-Recl. run.)
2862
AR successful (AR successful)
2864
AR: 1pole trip permitted by inter-
nal AR (AR 1p Trip Perm)
2865
AR: Synchro-check request (AR
Sync.Request)
2871
AR: TRIP command 3pole (AR
TRIP 3pole)
2889
AR 1st cycle zone extension
release (AR 1.CycZoneRel)
2890
AR 2nd cycle zone extension
release (AR 2.CycZoneRel)
2891
AR 3rd cycle zone extension
release (AR 3.CycZoneRel)
SIPROTEC, 7VK61, Manual
C53000-G1176-C159-3, Release date 05.2009
Function
Type
of In-
for-
matio
n
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Autoreclosure
OUT
*
Log Buffers
Configurable in Matrix
ON
*
LED
ON
*
LED
ON
*
LED
*
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
*
LED
ON
m
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
m
LED
*
*
LED
ON
m
LED
*
*
LED
*
*
LED
*
*
LED
Appendix
A.8 Information List
IEC 60870-5-103
BO
40
174
1
No
BO
40
175
1
No
BO
40
118
2
Yes
BO
40
143
1
No
BO
40
197
2
No
BO
40
148
2
Yes
BO
40
149
2
Yes
BO
40
150
2
Yes
BO
40
151
2
Yes
BO
40
154
2
Yes
BO
40
155
2
Yes
BO
40
157
2
Yes
BO
40
158
2
Yes
BO
40
159
2
Yes
BO
40
130
2
Yes
BO
94
128
1
No
BO
40
152
1
No
BO
40
153
1
No
BO
94
129
1
No
BO
BO
40
161
1
No
BO
40
162
1
No
BO
40
164
1
Yes
BO
40
165
2
Yes
BO
40
171
2
Yes
BO
40
160
1
No
BO
40
169
1
No
BO
40
170
1
No