Plessey Code

Plessey Code
Status (Plessey Code)
Usage:
Used primarily in library and retail applications.
Definition:
Plessey Code consists of pairs of wide and narrow bars representing binary
data which, taken in units of 12, define hexadecimal characters.
Serial Cmd:
<K487,status,check character output status,0,minimum symbol length>
Default:
Disabled
Options:
0 = Disabled
Check Character Output Status (Plessey Code)
Definition:
When this field is enabled, the check character will be output with symbol
data. When disabled, the check character will not be output with symbol
data.
Serial Cmd:
<K487,status,check character output
length>
Default:
Disabled
Options:
0 = Disabled
Minimum Symbol Length (Plessey Code)
Definition:
This field specifies the minimum number of characters the MS-1 will recognize,
including a check character.
Serial Cmd:
<K487,status,check character output
Default:
0
Options:
0 to 32
7-14
1 = Enabled
status,0,minimum symbol
1 = Enabled
status,0,minimum symbol