Symbol Length (Codabar)
Definition:
Specifies the number of characters that the MS-1 will recognize, including
start and stop check characters. The
Note: When setting Symbol Length to any value other than 0, add 2 to
account for reserved spaces. For example, if your symbol has 3 characters,
set Symbol Length to 5.
Note: If Symbol Length is set to 0 and Symbol Length Status is set to Any/
Minimum, all symbol lengths are decoded.
Serial Cmd:
<K471,status,0,start/stop output status,0,symbol length
length,check character status,check character output>
Default:
6
Options:
0 to 32
Check Character Status (Codabar)
Definition:
When disabled, the MS-1 will not perform any character checking calculations
on decoded Codabar symbols.
When set to Modulus 16, the MS-1 will perform a Modulus 16 check character
calculation on the symbol. If the symbol does not pass this calculation, it will
not be decoded.
Serial Cmd:
<K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character
Default:
Disabled
Options:
0 = Disabled
1 = Enabled (Modulus 16)
Check Character Output (Codabar)
Definition:
When this field is disabled and a check character calculation is enabled, the
MS-1 will strip the verified check character from the symbol data output. This
condition must be accounted for if a minimum length is also being used.
When enabled, the MS-1 will output the check character as part of the
symbol data. This condition must be accounted for if a minimum length is
also being used.
Serial Cmd:
<K471,status,0,start/stop output status,0,symbol length status,symbol
length,check character
Default:
Disabled
Options:
0 = Disabled
MS-1 Scan Engine User Manual
status,check character output>
status,check character
1 = Enabled
Symbologies
status,symbol
output>
7-7