Code 93

Usage:
Used in some clinical applications.
Definition:
Code 93 is a variable-length, continuous symbology employing four element
widths. Each Code 93 character has nine modules that may be either black
or white. Each character contains three bars and three spaces.
Serial Cmd:
<K475,status,0,minimum symbol length>
Default:
Disabled
Options:
0 = Disabled
Minimum Symbol Length (Code 93)
Definition:
Specifies the minimum number of characters that the MS-1 will recognize,
not including the start and stop check characters. The MS-1 ignores any
symbol smaller than the specified length.
Note: When setting Minimum Symbol Length to any value other than 0,
add 1 to account for a reserved space. For example, if your symbol has 3
characters, set Symbol Length to 4.
Serial Cmd:
<K475,status,0,minimum symbol
Default:
10
Options:
0 to 32
MS-1 Scan Engine User Manual
1 = Enabled
length>
Symbologies