Symbol Length #1 (Interleaved 2 of 5)
Usage:
Useful in applications where I 2/5 symbols of a specific length are
required.
Definition:
The Symbol Length # 1 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
Serial Cmd:
<K472,status,check character status,check character
#1,symbol length #2>
Default:
10
Options:
0 to 32
Symbol Length #2 (Interleaved 2 of 5)
Usage:
Useful in applications where I 2/5 symbols of a specific length are
required.
Definition:
The Symbol Length # 2 field is one of two fields against which the
decoded symbol is compared before accepting it as valid or rejecting it.
Serial Cmd:
<K472,status,check character status,check character output,symbol length
#1,symbol length
Default:
6
Options:
0 to 32
Range Modes (Interleaved 2 of 5)
Variable Length
To set for any length, Symbol Length # 1 and Symbol Length # 2 must both equal zero.
Minimum Length
To set for minimum length, both Symbol Length # 1 and Symbol Length # 2 must be equal
to each other and set to the desired minimum length, but these numbers cannot be zero.
Fixed Length
To set for a fixed length, Symbol Length #1 and Symbol Length #2 must not be equal to
each other. The symbol will be decoded if the character length is equal to Symbol Length
# 1 or Symbol Length # 2. If Symbol Length # 1 equals zero, then the symbol will only be
decoded if it is equal to Symbol Length # 2. If Symbol Length # 2 equals zero, then the
symbol will only be decoded if it is equal to Symbol Length # 1.
Examples:
Length 1
0
>0
0
>0
>0
MS-1 Scan Engine User Manual
#2>
Length 2
0
0
>0
>0
Same value as Length 1
output,symbol length
Required Symbol Length
Any
Exactly Length 1
Exactly Length 2
Exactly Length 1 or Length 2
Length 1 up to maximum symbol length (Range:
Length 1 to 32)
Symbologies
7-9
Need help?
Do you have a question about the MS-1 and is the answer not in the manual?