Supermicro C9Z390-PGW User Manual page 77

Hide thumbs Also See for C9Z390-PGW:
Table of Contents

Advertisement

Chapter 4: AMI BIOS
TDC Enable
This feature enables TDC. The options are Disabled or Enabled.
TDC Current Limit
Enter a value for the TDC Current Limit, with each whole number
equating to 1/8A (i.e. 1000 = 125A). The range is 0-32767. The
default is 800.
TDC Time Window
This feature controls the TDC Time Window. The options are 1
ms, 2 ms, 3 ms, 4 ms, 5 ms, 6 ms, 7 ms, 8 ms, and 10 ms.
TDC Lock
This feature enables TDC Lock. The options are Disabled or
Enabled.
GT VR Settings
VR Config Enable
This feature enables VR Config. The options are Disabled or
Enabled.
AC Loadline
Enter a value for AC Loadline.
DC Loadline
Enter a value for DC Loadline.
PS Current Threshold1
Enter a value for PS Current Threshold1. The range is 0-512.
The default is 80.
PS Current Threshold2
Enter a value for PS Current Threshold2. The range is 0-512.
The default is 20.
PS Current Threshold3
Enter a value for PS Current Threshold3. The range is 0-512.
The default is 4.