Fault Code F; Table 010-8: Fault Code Summary - Miele KM 5773 Technical Information

Table of Contents

Advertisement

KM 5773
Fault code
FE 85
FE 86
FE 99

Table 010-8: Fault Code Summary

Remedy:
See the appropriate fault code.
3.2

Fault Code F

Symptom:
The cooktop control is shut off. F flashes in the appropriate burner display. At the
same time, a 3-second beep is activated every 30 seconds for up to 10 minutes
(see Section 010-2.6).
Cause:
One or more touchpads has been touched or covered for more than 10 seconds.
This can be caused by an object that has been placed on the cooktop or by
soiling.
Remedy:
Remove any object/soiling covering the controls.
Cause
Remedy
Connection cable
between filter/control
Check connection cable (including plugs) between
electronic (N1) and left
filter/control electronic (1N1) and left power
power electronic (1A3)
electronic (1A3), and replace it if necessary.
defective.
Check PTC and replace the burner with PTC as
necessary; see Section 010-4.7.
Check left power electronic (1A3) and replace it as
Electronic module fault.
necessary; see Section 010-4.9.
Check left filter/control electronic (1N1) and replace
it as necessary; see Section 010-4.10.
Connection cable
between filter/control
Check the connection cable (including plugs)
electronic (2N1) and
between filter/control electronic (2N1) and right
right power electronic
power electronic (2A3), and replace it as necessary.
(2A3) defective.
Check PTC and replace the burner with PTC as
necessary; see Section 010-4.7.
Check right power electronic (2A3) and replace it as
Electronic module fault
necessary; see Section 010-4.9.
Check right filter/control electronic (2N1) and replace
it as necessary; see Section 010-4.10.
Overheating of the
cooktop, for example,
None. After cooldown, the cooktop can be used
by a pot that has boiled
again.
dry.
Check the fan (refer to Section 010-4.1) and replace
Overheating of the
it as necessary; refer to Section 010-4.12.
cooktop due to
Make sure there is sufficient ventilation in a built-in
insufficient ventilation.
installation.
Check the temperature sensor and replace the
burner with PTC as necessary; refer to
Section 010-4.7.
Overheating caused
Check the connecting plug of the temperature
damage to a burner's
sensor to the power electronic (1A3/2A3/3A3) for
PTC.
good fit.
Replace the power electronic (1A3/2A3/3A3); refer
to Section 010-4.9.
29
Technical Information

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents