Table 7-1. E1/T1 Port Configuration Parameters (Continued)
Field
Linecode
Cablelength
(T1
only)
Gain (T1 only)
Clock Source
FDL (T1 only)
Local Loopback
Remote Loopback
(T1 only)
Description
The type of linecode. Possible values are:
For an E1 line:
• HDB3
• AMI
For a T1 line:
• B8ZS
• AMI
The recommended maximum cable length.
The gain on this interface.
The source of the Transmit Clock. Possible
sources include:
• Line - The recovered receive clock is used
as the transmit clock.
• Internal - The local clock is used as the
transmit clock.
The type of FDL used on this interface. Possible
types include:
• ANSI
• AT&T
• Both - ANSI and AT&T FDl are both used
on this interface.
A request to use a local loopback. A local
loopback can be performed using:
• No Loopback
• Payload Loopback
• Line Loopback
• Diag Loopback
A request to use a remote loopback. A remote
loopback can be performed using:
• No Remote Loopback
• Remote Line
• Remote Payload