To configure the device's port redundancy configuration:
Avaya G350 Manager User Guide
Table 11-1. Port Redundancy Fields(Continued)
Field
Secondary
Switch Over
Switch Back
1. Enter an amount in the
2. Select one of the
3. If you selected
After
switch back in the
4. Update the device. For more information on updating the device,
refer to
"Updating the Device" on page
Description
The secondary port of the port redundancy
pair.
The minimum time between switching
between the ports in a port redundancy pair.
The amount of time after the primary port
link is reestablished after which the primary
port takes over from the secondary port.
Possible values include:
• Disabled - The primary port does not
take over from the secondary port.
• Immediately - The primary port takes
over from the secondary port as soon as
the primary port link is reestablished.
• After x sec- The primary port takes over
from the secondary port x seconds after
the primary port link is reestablished.
Switch Over
field.
Switch Back
option buttons.
x
, enter the number of seconds for the
sec
x
field.
After
sec
Port Redundancy
145.