Avaya G350 Manager User Guide
Table 4-2. Port Configuration - Power Fields (Continued)
Field
Detection Status
Power Priority
Power Maintenance
Description
The operational state of power on this port.
Possible states include:
• Searching - Port is currently being
polled.
• OK - This port is supplying power to an
IP telephone.
• Failed - This port is currently not
supplying power to an IP telephone.
The priority of the power being supplied by
this port. When the demand for power
exceeds the modules capacity, ports with
lower priority will be prevented from
supplying power before ports with a higher
priority. Possible priorities include:
• Critical
• High
• Low
The port's operational power status. Possible
statuses include:
• OK - The port current is within the
normal range.
• Under Current - The port current is
below the minimum acceptable value.
• MPS Absent - Unable to detect power
status.
Power Over Ethernet