Ieee Standards - Dell EMC S4112F-ON Installation Manual

S4112–on series
Table of Contents

Advertisement

Parameter
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Table 10. AC power requirements
Parameter
Power supply
Maximum current draw per system
Maximum power consumption
Typical power consumption
Table 11. DC power requirements
Parameter
Minimum and maximum input voltage range
Maximum input current
Start up VDC
Start off VDC

IEEE standards

The S4112–ON Series (S4112F-ON and S4112T-ON) switch complies with the following IEEE standards:
802.1ab (LLDP)
Specifications
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours per year.
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
5% to 85% (RH), non-condensing
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
–40° to 65°C (–40° to 149°F)
5% to 95%, non-condensing
S4112F-ON: 180W, 614 BTU/hr
S4112T-ON: 200W, 682 BTU/hr
10,000 feet (3,048 meters)
39,370 feet (12,000 meters)
Dell EMC Spec SV0115
Specifications
100–240 VAC 50/60 Hz
2A/1.7A at 100/120V AC 1A/0.8A at 200/240V AC
S4112F-ON: 180W
S4112T-ON: 200W
S4112F-ON: 90W
S4112T-ON: 120W
Specifications
−40V, –72V DC, 5A Max
−40V/5A, −48V/4.2A, −72V/2.8A
39.0 ± 1.5 V
37.5 ±1.5 V
Specifications
39