Ieee Standards - Dell EMC S5048F-ON Installation Manual

Table of Contents

Advertisement

Table 6. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Table 7. AC power requirements
Parameter
Power supply
Maximum current draw per switch
Maximum power capability
Typical power consumption
Table 8. DC power requirements
Parameter
Minimum/maximum input voltage range
Input power at full load
Input current at full load

IEEE standards

The S5048F-ON switch complies with the following IEEE standards.
802.1ab (LLDP)
802.1ax (Layer 2)
802.1d, 802.1w, 802.1s, 802.1x (Mgmt/Security), 802.3x (Layer 2)
802.3 (1000BASE-KX)
802.3ba (40GbE and 100GbE ports)
40
Specifications
Specifications
0°C to 45°C (32°F to 113°F)
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours per year.
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
–40°F to 70°C (–40°F to 158°F)
5% to 90%, non-condensing
500 W = 1706 BTU/Hr
10,000 feet (3,048 meters)
39,370 feet (12,000 meters)
Dell EMC Spec SV0115
Specifications
100–240 VAC 50/60 Hz
5A/4.16A at 100/120V, 2.5A/2.08A at 200/240V
500 Watts
200 Watts
Specifications
−40.5, -48V, –60V
-40.5/500W, -48V/500W, -60V/500W
-40.5V/12.35A, -48V/10.42A, -60V/8.33A

Advertisement

Table of Contents
loading