LinMot E1100-CO Drive Data Sheet & Installation Manual page 19

Documentation for installing the following drives, rs485, profi bus, rs232, easy steps, canopen, devicenet
Hide thumbs Also See for E1100-CO:
Table of Contents

Advertisement

Installation Guide E1100
X6:
Digital I/O (only available on E1100-GP (-HC, -XC))
DSUB-25 (f)
All Inputs:
Direct interfacing to digital 24VDC PLC outputs.
Input Current:
Low Level:
All Outputs:
Short circuit and overload protected high side switches
Voltage:
Max. Current:
Outputs may directly drive inductive loads. Do not connect any capacity because of the peak current!
X7 - X8
RS485/CAN
RJ-45
Use twisted pair (1-2, 3-6, 4-5, 7-8) cable for wiring.
The built in CAN and RS485 terminations can be activated by S3.2 and S3.3.
X7 is internally connected to X8 (1:1 connection)
X9:
Profibus DP (only available on E1130-DP (-HC, -XC))
NTI AG, LinMot
1mA
-30 to 8.5VDC
24VDC
100mA
1
RS485_Rx+
2
RS485_Rx-
3
RS485_Tx+
4
GND
5
GND
6
RS485_Tx-
7
CAN_H
8
CAN_L
case
Shield
1
Not connected
2
Not connected
3
RxD/TxD-P
4
CNTR-P
5
GND
6
+5V
7
Not connected
8
RxD/TxD-N
9
Not connected
case
Shield
Installation Guide E1100 23/08/2018
Sample Rate:
1ms
High Level:
20.5 to 30VDC
Update Rate
1ms
Peak Current:
370mA (will shut down if exceeds)
A
B
Y
Z
(isolated)
(isolated)
Page 19/27