LinMot E1100-CO Drive Data Sheet & Installation Manual page 15

Documentation for installing the following drives, rs485, profi bus, rs232, easy steps, canopen, devicenet
Hide thumbs Also See for E1100-CO:
Table of Contents

Advertisement

Installation Guide E1100
X3:
Motor
For UL applications the motor phases must be wired on X2 and not on X3!
DSUB-9 (f)
Note:
Use +5V (X3.3) and AGND (X3.8) only for motor internal Hall Sensor supply (max. 100mA).
Caution:
Do NOT connect AGND (X3.8) to ground or earth!
It is only allowed to use X3 for connecting the motor phases if RMS current is below 5A and peak current
is below 7.5A.
Motor Wiring for Phase Currents above 5A RMS 7.5A peak (recommended general wiring)
Important:
If motor phase current exceeds 5A
For UL applications the motor phases have to be wired on X2 and not on X3!
NTI AG, LinMot
LinMot Motor:
1
Motor Phase 1+
2
Motor Phase 2+
3
+5VDC
4
Sensor Sine
5
Temp. In
6
Motor Phase 1-
7
Motor Phase 2-
8
AGND
9
Sensor Cosine
case
Shield
RMS
Installation Guide E1100 23/08/2018
or 7.5A
, motor phases must be wired to X2.
peak
3-phase EC-Motor:
+5VDC (Hall Supply)
Hall 1
Hall 3
AGND (Hall Supply)
Hall 2
Page 15/27