Example Configuration - Teach Height Area - Leuze electronic CSL710-T05-1280.A-M12 Original Operating Instructions

Switching light curtain csl 710 series
Table of Contents

Advertisement

Digital Output 2 Settings
Area mapping 8 ... 1
(OR combination)
 Map the configured areas 1 and 8 (OR-linked) to the corresponding switching output.
Digital Output 2 Settings
Area mapping 8 ... 1
(OR combination)
10.2
Example configuration – Teach height area
The following tables show an example configuration for teaching two height areas and the assignment of
two outputs.
• Height area 01 is to be applied to output pin 2 of interface X1.
• Height area 02 is to be applied to output pin 5 of interface X1.
 Teach height area 1.
A height area is automatically defined using an object.
When teaching a height area, all free beams are combined into one height area.
To define the entire beam area as a height area, a height area is taught without an object.
Description / variables
Configuration of beams in areas
Teach height area
 Configure pin 2 as area output.
Description / variables
Configuration of digital inputs/outputs
IO Function
 Map pin 2 to configured height area 1.
Description / variables
Configuration of pin 2
Area mapping 8 ... 1
(OR combination)
 Teach height area 2.
Description / variables
Configuration of beams in areas
Teach height
 Configure pin 5 as area output.
Leuze electronic
0b10000000
0b10000001
Value: area 1
Active: all beams free
Not active: one beam interrupted
Value: 3 = Area output (area 1 ... 8)
0b00000001
Value: area 2
Active: all beams free
Not active: one beam interrupted
CSL 710
Example configurations
All free beams are configured as area 1.
The area output signals the logical states of beam
areas 1 ... 8.
Every area is displayed as a bit.
All free beams are configured as area 2.
66

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csl710-r05-1280.a/l-m12

Table of Contents