Leuze electronic S20 Series Operation Instructions Manual
Leuze electronic S20 Series Operation Instructions Manual

Leuze electronic S20 Series Operation Instructions Manual

Safety switches
Hide thumbs Also See for S20 Series:

Advertisement

Quick Links

S20
Safety Switches
S A F E I M P L E M E N T A T I O N A N D O P E R A T I O N
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Advertisement

Table of Contents
loading

Summary of Contents for Leuze electronic S20 Series

  • Page 1 Safety Switches S A F E I M P L E M E N T A T I O N A N D O P E R A T I O N CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net...
  • Page 2: Table Of Contents

    About this document .................... 5 Other applicable documents ....................5 Used symbols and signal words ..................6 Safety........................7 Proper use ........................... 7 Competent personnel......................9 Responsibility for safety ....................... 9 Exemption of liability ......................9 Device description ..................... 10 Functions ......................
  • Page 3 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net...
  • Page 4: About This Document

    About this document About this document Other applicable documents The information on the S20 Safety Switch is divided into two documents. Docu- ment "Application information" contains only the most important safety notices. For the safe implementation, testing and operation, download document "Safe implementation and operation of the S20"...
  • Page 5: Used Symbols And Signal Words

    About this document Used symbols and signal words Table 1.2: Warning symbols and signal words Symbol for dangers NOTICE Signal word for property damage Indicates dangers that may result in property damage if the measures for danger avoidance are not followed. CAUTION Signal word for minor injury Indicates dangers that may result in minor injury if the measures for dan-...
  • Page 6: Safety

    Safety Safety Before using the Safety Switch, a risk evaluation must be performed according to valid standards (e.g. EN ISO 12100-1, EN ISO 13849-1, EN ISO 14121). For mounting, operating and testing, document "Safe implementation and operation of the S20" as well as all applicable national and international standards, regula- tions, rules and directives must be observed (e.g.
  • Page 7 Safety S20 Safety Switches must be connected in such a way that a dangerous state can only be activated while the protective device is closed and so that the dangerous state stops upon opening of the protective device. It must not be used if the point of operation can be accessed during the lag time before the dangerous state has ended.
  • Page 8: Competent Personnel

    • regular testing by competent personnel Exemption of liability Leuze electronic GmbH + Co. KG is not liable in the following cases: • Safety Switch is not used as intended • safety notices are not adhered to • mounting and electrical connection are not properly performed •...
  • Page 9: Device Description

    Device description Device description The Safety Switch of the S20 series is an electro-mechanical switching device in a housing made of glass-fibre-reinforced and non-combustible plastic; the device satisfies protection rating IP 67. The standard design facilitates easy replacement. By means of the funnel-shaped insertion opening, the actuator self-centres, even if the door is slightly misadjusted.
  • Page 10 Device description 24.2 30.8 14.2 30.8 Figure 3.1: Dimensions S20-P3C1-M20-FH and S20-P1C1-M20-FH in mm 52.2 14.1 31.6 Figure 3.2: Dimensions S20-P1C3-M20-LH in mm CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net...
  • Page 11: Functions

    Functions The deflection head can be turned in 90° increments and set to 5 approach direc- tions. A selection of different actuators ensures that the Safety Switch can be mounted in any position. Figure 3.3: Approach directions Functions The Safety Switch signals to the safety switching device whether the protective device is closed.
  • Page 12: Mounting

    Mounting Mounting WARNING Serious accidents may result if the Safety Switch is not mounted properly! The protective function of the Safety Switch is only ensured if appropriately and professionally mounted for the respective, intended area of application. Mounting may only be performed by competent personnel. Observe standards, regulations and these instructions.
  • Page 13: Mounting The Safety Switch

    Mounting Lift the deflection head and turn in the desired approach direction. Tighten the 2 screws on the deflection head with 0.7–0.9Nm. Close unused opening with the dust cover. Mounting the Safety Switch Prerequisites for mounting: • deflection head has been set •...
  • Page 14: Mounting The Actuator

    Mounting Position washers and screw down Safety Switch with 2–3Nm. Mounting the actuator NOTICE The Safety Switch may be damaged if mounted improperly! Use separate mechanical limit stop for the moving part of the protective device. Align actuator so that it does not hit or rub against the edges of the insertion opening.
  • Page 15 Mounting Align actuator. Play for the actuator in the closed state: 0.5–4.5mm. Secure actuator with rivets or tamperproof screws so that it cannot be detached. CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net...
  • Page 16: Electrical Connection

    Electrical connection Electrical connection WARNING Serious accidents may result if the electrical connection is faulty! Electrical connection may only be performed by competent personnel. Connecting the contact block DANGER Risk of death by electric shock! Interrupt the voltage supply to the Safety Switch. Prerequisites for the electrical connection: •...
  • Page 17 Electrical connection Unscrew the housing cover. Connect the contact block according to the circuit diagram. +24V +24V S20-P3C1-M20-FH MSI-SR4 Var. B Var. A Figure 7.3: Connection example S20-P3C1-M20-FH +24V +24V S20-P1C1-M20-FH MSI-SR4 Var. B Var. A Figure 7.4: Connection example S20-P1C1-M20-FH CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net...
  • Page 18 Electrical connection Tighten cable terminal screws with 0.6–0.8Nm. Tighten the housing cover with 0.7–0.9Nm. CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net...
  • Page 19: Setting The Device Into Service

    Setting the device into service Setting the device into service Prerequisites: • Safety Switch is mounted and connected according to these instructions • operating personnel have been trained in the correct use Test the function of the Safety Switch (see chapter 9 "Testing"). The Safety Switch is then ready for use.
  • Page 20: To Be Performed Daily By The Operating Personnel

    Testing Electrical function WARNING Severe injuries may result if tests are not performed properly! Make certain that there are no persons in the danger zone. Stop the dangerous state and open the protective device. Make certain that the machine cannot be started while the protective device is open.
  • Page 21: Cleaning

    The nationally valid regulations for electro-mechanical components are to be observed when disposing. Service and support Contact data: Leuze electronic GmbH + Co. KG Liebigstraße 4 D-82256 Fürstenfeldbruck Phone: +49 8141 5350-111 CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net...
  • Page 22: Accessories

    Accessories Accessories Table 13.1: Actuators of the AC-AN series for the S20 Safety Switch Article Part No. Description AC-AN-S 63000 700 Straight AC-AN-A 63000 701 Angled AC-AN-F4 63000 702 Straight, flexible in 4 directions AC-AN-F2J2 63000 703 Straight, flexible in 2 directions, alignable in 2 directions AC-AN-SL 63000 704 Straight, long...
  • Page 23: Technical Data

    Technical data Technical data Table 14.1: General Switch type Interlock device without guard interlocking in accordance with EN 1088 Actuator, external AC-AN series: straight, angled, resilient, alignable Approach actuation directions 1 x above, 4 x side (90°) Approach speed min. 1mm/s, max. 0.5m/s Actuation force (extraction) Actuating path with forced separation min.
  • Page 24 Technical data Table 14.2: Safety Protection rating IP 67 Contact protection Protective insulation O Recoil tolerance 4.5mm Contact allocation S20-P3C1-M20-FH: 2 NC S20-P1C1-M20-FH: 1 NC + 1 NO S20-P1C3-M20-LH: 1 NC + 1 NO Contact material silver alloy Switching principle slow-action contact Opening of contact positive-forced...
  • Page 25: Ec Declaration Of Conformity

    EC Declaration of Conformity EC Declaration of Conformity Leuze electronic GmbH + Co. KG Liebigstraße 4 D-82256 Fürstenfeldbruck We hereby declare that the S20 Safety Switch (see name plate for part no.) in the form in which it is marketed by us conforms with the relevant safety and health...