To be performed periodically by competent personnel ............25 To be performed daily by the operating personnel ............26 Cleaning......................27 Disposing ......................28 Service and support ................... 29 Accessories ....................... 30 13.1 Accessory dimensional drawings ..................31 Technical data ....................34 Leuze electronic S200...
Page 4
EC Declaration of Conformity ................37 S200 Leuze electronic...
About this document About this document Other applicable documents The information on the S200 Safety Switch is divided into two documents. Docu- ment "S200 Application information" contains only the most important safety notices. For the safe implementation, testing and operation, download document S200 Safe implementation and operation from http://www.leuze.com/s200/ or...
Other symbols Symbol for tips Text passages with this symbol provide you with further information. Symbols for action steps Text passages with this symbol instruct you to perform actions. Placeholder in the product description for all variants S200 Leuze electronic...
Before using the Safety Switch, a risk evaluation must be performed according to valid standards (e.g. EN ISO 12100-1, EN ISO 13849-1, EN ISO 14121). For mounting, operating and testing, document S200 Safe implementation and oper- ation, application information as well as all applicable national and international standards, regulations, rules and directives must be observed.
S200 Safety Switches must be connected in such a way that a dangerous state can only be activated while the protective device is closed and so that the dangerous state stops upon opening of the protective device.
Safety Furthermore, the S200 Safety Switch must not be used under the following condi- tions: • high concentration of dust particles in the surrounding area • rapidly changing ambient temperature (leads to condensation) • in the event of strong physical shocks •...
• regular testing by competent personnel Exemption of liability Leuze electronic GmbH + Co. KG is not liable in the following cases: • Safety Switch is not used as intended • safety notices are not adhered to • mounting and electrical connection are not properly performed •...
Device description Device description The Safety Switch of the S200 series is an electro-mechanical switching device in a housing made of metal; the device satisfies protection rating IP 67. The standard design facilitates easy replacement. By means of the funnel-shaped insertion opening, the actuator self-centers, even if the door is slightly misadjusted.
Page 12
M20 in mm M12x1 Figure 3.2: Dimensions of S200-M4C1-M12 in mm (M12 plug dimensions) The deflection head can be turned in 90° increments and set to 5 approach direc- tions. A selection of different actuators ensures that the Safety Switch can be mounted in any position.
Moving the actuator in closes the safety contacts; moving the actuator out forces the safety contacts to open (e.g. upon opening of the protective device). As a result, the machine can only be switched on if the protective device is closed. S200 Leuze electronic...
Applications Applications The Safety Switch can be used for e.g. the following protective devices: • turning or swiveling moveable guards • laterally moveable protective gratings or sliding gates • heavy doors or rolling gates Leuze electronic S200...
Observe standards, regulations and these instructions. Protect the housing and deflection head from materials penetrating the enclo- sure (environmental conditions (see chapter 14)). Test to ensure proper function. Adjusting the deflection head Loosen the 2 screws on the deflection head. S200 Leuze electronic...
• Safety Switch and actuator can be well matched to one another mechani- cally and can be permanently mounted • accessible to qualified personnel for testing and replacement • difficult to access by operating personnel while the protective device is open Leuze electronic S200...
Align actuator so that it does not hit or rub against the edges of the insertion opening. Prerequisites for proper function: • actuator is not deformed or damaged • actuator is suitable for the Safety Switch Proper function is ensured only with original accessories (see chapter 13). S200 Leuze electronic...
Page 19
Mounting Wrong Correct Align actuator. Play for the actuator in the closed state: 0.5–5 mm. Secure actuator with rivets or tamperproof screws so that it cannot be detached. Leuze electronic S200...
• Safety Switch is mounted and connected according to these instructions • operating personnel have been trained in the correct use Test the function of the Safety Switch (see chapter 9). The Safety Switch is then ready for use. S200 Leuze electronic...
Testing Testing S200 Safety Switches are maintenance-free. Nevertheless, they must be replaced after maximum 1,000,000 switching cycles. Always replace the entire Safety Switch including actuator. For the testing intervals, observe nationally applicable regulations. Document all tests in a comprehensible manner.
Check the Safety Switch and actuator for damage or tampering. Make certain that the machine cannot be started while the protective device is open. Close the protective device and start the machine. Test whether the machine stops upon opening of the protective device. S200 Leuze electronic...
Prerequisites for cleaning: • protective device is opened and machine is switched off • voltage supply to the Safety Switch is interrupted Periodically clean the Safety Switch while the protective device is opened (e.g. with vacuum cleaner). Leuze electronic S200...
Friday, 8.00 a.m. to 16.00 p.m. (UTC +1) E-mail: service.protect@leuze.de Return address for repairs: Service Center Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen - Teck / Germany Leuze electronic offers a regular safety inspection by a competent person. Leuze electronic S200...
Approach speed min. 1 mm/s, max. 0.5 m/s Actuation force (pull-out) 10 N Actuating path with forced separation S200-M1C1-M20: min. 8.6 mm S200-M3C1-M20: min. 10.2 mm S200-M4C1-M20: min. 8.8 mm S200-M4C1-M12: min. 8.8 mm Mechanical life time according to 1,000,000 switching cycles...
Page 36
Environment Temperature range, operation –25 ... +80 °C Dirt levels, external, in accordance with EN 60947-1 These tables do not apply in combination with additional M12 plug or connecting cable except where these components are explicitly mentioned. S200 Leuze electronic...
Page 37
EC Declaration of Conformity EC Declaration of Conformity You can download this EC Declaration of Conformity as a PDF from: http://www.leuze.com/s200/ Leuze electronic S200...