NOTICE
Competent persons and approved purpose!
Only allow competent persons to perform the electrical connection.
Select the functions so that the light curtain can be used as intended (see chapter 2.1).
7.3
Device connections
The light curtain is provided with the following connections:
Device con-
nection
X1 on receiver M12 connector,
X2 on receiver M12 socket,
X3 on
transmitter
7.4
Digital inputs/outputs on connection X1
In the factory settings, the digital inputs/outputs are assigned with the following functions:
• IO 1 (pin 2): teach input
• IO 2 (pin 5): switching output (dark/inverted)
• IO 3 (pin 6): switching output (light/normal)
• IO 4 (pin 7): warning output
10k
X1-2/5
X1-3
Figure 7.4:
Digital input/output schematic diagram
NOTICE
Single assignment of input functions!
Each input function may only be used one time. If multiple inputs are assigned the same function, mal-
functions may occur.
7.5
Electrical connection – CSL 710
NOTICE
Light curtain grounding!
Ground the light curtain before establishing an electrical connection or connecting the voltage supply
(see chapter "Grounding the light curtain housings").
Leuze electronic
Type
8-pin
4-/5-pin
M12 connector,
5-pin
10k
Function
Control interface and data interface:
• Voltage supply
• Switching outputs and control inputs
• Configuration interface
Synchronization interface
Synchronization interface (for all controller types)
CSL 710
Electrical connection
18 - 30 VDC
X1-1
100 mA (max. 250 mA)
X1-6/7
GND
X1-3
41