7.3

Device connections

The light curtain is provided with the following connections:
Device con-
nection
X1 on receiver M12 connector,
X2 on receiver M12 socket,
X3 on
transmitter
7.4

Digital inputs/outputs on connection X1

In the factory settings, the digital inputs/outputs are assigned with the following functions:
• IO 1 (pin 2): teach input
• IO 2 (pin 5): switching output (dark/inverted)
• IO 3 (pin 6): switching output (light/normal)
• IO 4 (pin 7): warning output
10k
X1-2/5
X1-3
Figure 7.4:
Digital input/output schematic diagram
NOTICE
Single assignment of input functions!
 Each input function may only be used one time. If multiple inputs are assigned the same function, mal-
functions may occur.
7.5
Electrical connection – CSL 710
NOTICE
Light curtain grounding!
 Ground the light curtain before establishing an electrical connection or connecting the voltage supply
(see chapter "Grounding the light curtain housings").
Leuze electronic
Type
8-pin
4-/5-pin
M12 connector,
5-pin
10k
Function
Control interface and data interface:
• Voltage supply
• Switching outputs and control inputs
• Configuration interface
Synchronization interface
Synchronization interface (for all controller types)
CSL 710
Electrical connection
18 - 30 VDC
X1-1
100 mA (max. 250 mA)
X1-6/7
GND
X1-3