Check Alignment; Setting The Function Reserve - Leuze electronic CSL710-T05-1280.A-M12 Original Operating Instructions

Switching light curtain csl 710 series
Table of Contents

Advertisement

If teach is successful, both bars display the maximum value.
Figure 8.7:
Display after successful teach
The next configuration step is to check the alignment.
8.3

Check alignment

Prerequisites:
• The light curtain must first be correctly aligned and a teach must be performed.
 Check whether the green LEDs on the receiver control panel and transmitter illuminate continuously.
 Use the bar graph indicator to check whether the light curtain is optimally aligned, i.e., whether the max-
imum is reached for both the first beam (FB) and the last beam (LB) in the bar graph indicator.
 Use the bar graph indicator to check the optimum alignment of the light curtain if you have corrected an
error that occurred.
The next configuration steps:
• Perform extended configurations on the receiver control panel if necessary (see chapter 8.5)
• Starting up the CSL 710 light curtains (see chapter 9)
8.4

Setting the function reserve

The function reserve can be set to three levels:
• High function reserve (low sensitivity)
• Medium function reserve
• Low function reserve (high sensitivity)
The function reserve can be set via the receiver control panel and the
ware (see chapter 11).
The function reserve can be set via the receiver control panel, via the interface (see chapter 9) or via the
Sensor Studio
configuration software (see chapter 11).
The sensitivity levels (e.g., high function reserve for stable operation, medium function reserve
and low function reserve) are configured ex works with "high function reserve for stable
operation". The "low function reserve" configuration enables the detection of partially transparent
objects.
The structure of the configuration in the receiver control panel menu is as follows:
Level 0
Level 1
Main Settings
Commands
Operational setting
Leuze electronic
Level 2
Description
Teach
Filter depth
Beam mode
Function reserve
High
CSL 710
Starting up the device - Basic configuration
Sensor Studio
Reset
Factory settings
Medium
Low
configuration soft-
49