1
X 2
X1
3
PWR IN/OUT
1
2
3
4
Figure 7.5:
Electrical connection – CSL 710
Connect connection X2 to connection X3 using the appropriate synchronization cable.
Connect connection X1 to the voltage supply and the control using the appropriate connection cable.
7.5.1
X1 pin assignment – CSL 710
8-pin, M12 plug (A-coded) for connecting to PWR IN/digital IO and IO-Link interface.
1
1
Figure 7.6:
X1 connection – CSL 710
Table 7.2:
Pin
X1 - Logic and power on the receiver
1
VIN: +24 V DC supply voltage
2
IO 1: input/output (configurable)
Ex works: teach input (Teach In)
3
GND: ground (0 V)
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
Factory setting: switching output (dark/inverted)
Leuze electronic
4
Receiver (R)
Transmitter (T)
Connection cable (M12 socket, 8-pin), see table 16.3
Synchronization cable (M12 plug/socket, 5-pin), see table 16.4
M12 plug (8-pin, A-coded)
X1 pin assignment – CSL 710
2
X3
CSL 710
Electrical connection
42