Defining Configurations Via The Io-Link Master Module Of The Plc-Specific Software; Parameter/Process Data For Io-Link - Leuze electronic CSL710-T05-1280.A-M12 Original Operating Instructions

Switching light curtain csl 710 series
Table of Contents

Advertisement

9.2

Defining configurations via the IO-Link master module of the PLC-specific software

General prerequisites:
• The light curtain has been mounted (see chapter 6) and connected (see chapter 7) correctly.
• The basic configuration has been performed (see chapter 8).
• IO-Link-specific basic configurations have been performed.
IO-Link bit rate selected
The IO Device Description (IODD) can be used both with connected light curtain for direct con-
figuration or without connected light curtain for creating device configurations.
The IODD files are supplied with the product. The IODD can also be downloaded from the
Internet at www.leuze.com.
 Open the configuration software of the IO-Link master module.
 Configure the following parameters:
- Beam mode (parallel-, diagonal-, crossed-beam)
- Blanking settings
- Teach settings
 Perform a teach. This is possible via the receiver control panel or the control group in the IO-Link pro-
cess data (IO-Link object 2).
 If necessary, configure additional parameter/process data (see chapter 9.3).
 Save the configuration via the control group in the IO-Link process data (IO-Link object 2).
The IO-Link-specific configurations are performed and copied to the device. The device is prepared for
process mode.
9.3

Parameter/process data for IO-Link

The parameter data and process data are described in the IO-Link Device Description (IODD) file.
Details on the parameters and on the structure of the process data can be found in the .html document,
which is contained in the IODD zip file.
Sub-index access is not supported.
Overview
Group
Group 1
Group 2
Group 3
Group 4
Group 5
Group 6
Group 7
Group 8
Group 9
Group 10
Leuze electronic
Group name
System commands (see page 57)
CSL 710 status information (see page 57)
Device description (see page 57)
General configurations (see page 59)
Blanking settings (see page 59)
Teach settings (see page 61)
Digital IO pin N settings (N = 2, 5, 6, 7) (see page 61)
Autosplitting (see page 62)
Configuration for block evaluation of beam areas (see page 63)
Evaluation functions (see page 64)
Starting up the CSL 710 with IO-Link interface
CSL 710
56

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csl710-r05-1280.a/l-m12

Table of Contents