Inversion Of The Switching Behavior (Light/Dark Switching); Defining The Filter Depth - Leuze electronic CSL710-T05-1280.A-M12 Original Operating Instructions

Switching light curtain csl 710 series
Table of Contents

Advertisement

Level 0
Level 1
 Select Digital IOs > IO Logic > Positive PNP.
 Select Digital IOs > IO pin 5 > Teach height > Execute.
The height area is automatically configured as an area output.
IO Function > Area Out must also be selected.
8.5.2

Inversion of the switching behavior (light/dark switching)

Light/dark switching is configured with this configuration.
For all digital process interfaces, the configuration can also be performed via the interface (see
chapter 9) or via the
The following example shows how the switching output is switched from light switching (normal) to dark
switching (inverted).
The structure of the configuration in the receiver control panel menu is as follows:
Level 0
Level 1
Digital IOs
IO Logic
IO Pin 2
 Select Digital IOs > IO Pin 2 > Inversion > Inverted.
8.5.3

Defining the filter depth

The filter depth is used to specify that an evaluation of the measurement values occurs only once the beam
states are stable over multiple measurement cycles.
Example: with a filter depth of "5", five measurement cycles must be consistent before an evaluation is
performed. For further information, see also the description of interference suppression (see chapter 4.8).
For all digital process interfaces, the configuration can also be performed via the interface (see
chapter 9) or via the
When configuring the filter depth, you can enter values of up to 255. Values above 255 (to 299)
are not accepted and must be entered again.
The structure of the configuration in the receiver control panel menu is as follows:
Leuze electronic
Level 2
Description
Teach height
Execute
Area logic
AND
Start beam
(enter value)
End beam
(enter value)
Sensor Studio
configuration software (see chapter 11).
Level 2
Description
Positive PNP
IO Function
Trigger input
Inversion
Normal
Teach height
Execute
Area logic
AND
Start beam
(enter value)
End beam
(enter value)
Sensor Studio
configuration software (see chapter 11).
CSL 710
Starting up the device - Basic configuration
Exit
OR
Negative NPN
Teach input
Area output
Inverted
Exit
OR
Warning output
52

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csl710-r05-1280.a/l-m12

Table of Contents