Ametek IntelliPoint RF RMT Series Installation And Operating Instructions Manual page 66

Two-wire point level switch with manual calibration/set point
Table of Contents

Advertisement

RMTXX1 Series - IntelliPoint RF™ Instruction Manual
7.2
ATEX Control Drawings (Continued)
1 2 3 4 5 6 - 7 8 9 10 - 11 12 13 14
S a R b T 2 - c
0 d e - * * * *
a
b
2
c
Reference SIL Manual (SXRXT) For Ordering Detail
COLUMNS 11 AND UP, DO NOT AFFECT SAFETY
a = 2 SIL LEVEL 2
b = MEASUREMENT OPTIONS:
N = 2 pF AUTO-CAL
H = 0.5 pF AUTO-CAL (HIGH SENSITIVITY)
L = 2 pF FIXED
T = 10 pF AUTO-CAL
V = 10 pF FIXED
P = 0.5 pF FIXED (HIGH SENSITIVITY)
2 = ATEX APPROVAL, M20 HOUSING
c = 1-9, A-K CABLE OPTIONS, REMOTE
d e
d, e = SENSING ELEMENTS: 00, 02, 04, 06, 07, 09, 11-21, 24-28,
60-62, 64, 66, 72, 73, 85, 90-94.
700-1202-001
0 0
700-1202-014
2
4
700-1202-041
6
700-1202-031
700-1202-010
7
700-1202-033
9
1 1
700-0201-005
2
700-0201-005 (HAST C)
700-0201-019
3
700-0202-002
4
5
700-0202-043
6
700-0002-360
700-0202-029
7
700-0001-022
8
9
700-0002-023
2 0
700-0209-002
1
700-0202-043 (HAST-C)
4
700-0005-285
5
700-0005-285 (HAST-C)
6
700-0220-001
7
700-0221-002
8
700-1202-051
6 0
700-0204-038
1
700-0204-002
700-0204-048
2
4
700-0204-024
6
700-0204-022
7 2
700-0201-027
700-0201-028
3
8 5
700-9000-494
9 0
700-0201-059
1
700-1202-015
2
700-1202-045
3
700-1202-055
4
700-0209-024
60
SIL, ATEX APPROVED
REMOTE, 2-WIRE, INTELLIPOINT
MODEL NUMBERING SYSTEM
SHT 8 OF 9
420-0004-175-CD ISS. 10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellipoint rf rgt series

Table of Contents