Section 6: Specifications (Continued)
Approvals
Explosion-proof for use in Class I, Division 1, Groups A, B, C, and D,
Dust-Ignition proof for use in Class II and III, Division 1, Groups E, F,
and G; Non-incendiary for use in Class I, Division 2, Groups A, B, C,
and D; Suitable for use in Class II and III, Division 2, Groups F and G
Hazardous (Classified) Indoor and Outdoor (Type 4, 4X, IP66) Locations
with Intrinsically Safe connections to Class I, II, and III, Division 1,
Groups A, B, C, D, E, F, and G Hazardous (Classified) locations in
accordance with control drawing 420-0004-173-CD; Intrinsically Safe
for use in Class I, II, and III, Division 1, Groups A, B, C, D, E, F, and G
hazardous (Classified) locations in accordance with entity requirements
and control drawing 420-0004-173-CD.
ATEX (FM14ATEX0049)
Integral
II 1 G Ex ia IIC T5... T2 -30°C ≤ TAMB ≤ +70°C; IP66
II 1 D Ex ia IIIC T90°C -30°C ≤ TAMB ≤ +70°C; IP66
Temperature Class Process Temperature
T5
T4
T3
T2
II 1 G Ex ia IIC T5... T2 -30°C ≤ TAMB ≤ +70°C; IP66
Remote
II 1 D Ex ia IIIC T90°C -30°C ≤ TAMB ≤ +70°C; IP66
IECEX (FTZU 18.0007X)
Ex ia IIC T5 Ga
Ex ia IIIC T90ºC Da
-30ºC ≤ Ta ≤ 70ºC
2460
Reference control drawing 420-0004-562-CD for entity and installation requirements
Special Condition for Safe Use
1. THE EQUIPMENT SHALL NOT BE APPLIED IN AN EXPLOSIVE DUST ATMOSPHERE WHERE HIGH
ELECTROSTATIC CHARGING PROCESSES ARE PRESENT THAT COULD RESULT IN PROPAGATING
BRUSH DISCHARGES.
2. CONSULT THE MANUFACTURER IF DIMENSIONAL INFORMATION ON THE FLAMEPROOF JOINTS IS
NECESSARY.
3. AMBIENT TEMPERATURE RANGE:
-30°C TO +58°C FOR RXLX/SXRXTX INTELLIPOINT RF LEVEL SYSTEM
-30°C TO +70°C FOR RXTX/SXRXTX INTELLIPOINT RF TWO-WIRE POINT LEVEL SYSTEM
100°C