Deleting Vme Settings; Restoring Default Vme Settings; Remote Start - Motorola MVME6100 Installation And User Manual

Hide thumbs Also See for MVME6100:
Table of Contents

Advertisement

vmeCfg –e –rF70
Edits VMEbus Register Access Image Control Register state

Deleting VME Settings

To delete the changeable VME setting (restore default value), type the following at the firmware
prompt:
vmeCfg –d –m
Deletes Master Enable state
vmeCfg –d –i(0 - 7)
Deletes selected Inbound Window state
vmeCfg –d –o(0 - 7)
Deletes selected Outbound Window state
vmeCfg –d –r184
Deletes PCI Miscellaneous Register state
vmeCfg –d –r188
Deletes Special PCI Target Image Register state
vmeCfg –d –r400
Deletes Master Control Register state
vmeCfg –d –r404
Deletes Miscellaneous Control Register state
vmeCfg –d –r40C
Deletes User AM Codes Register state
vmeCfg –d –rF70
Deletes VMEbus Register Access Image Control Register state

Restoring Default VME Settings

To restore all of the changeable VME setting back to their default settings, type the following at
the firmware prompt:
vmeCfg –z

Remote Start

As described in the MOTLoad Firmware Package User's Manual, listed in
Documentation, remote start allows the user to obtain information about the target board,
download code and/or data, modify memory on the target, and execute a downloaded program.
These transactions occur across the VMEbus in the case of the MVME6100. MOTLoad uses
one of four mailboxes in the Tsi148 VME controller as the inter-board communication address
(IBCA) between the host and the target.
Chapter 3 MOTLoad Firmware
MVME6100 Installation and Use (V6100A/IH2)
Appendix C, Related
27