CONFIGURING YOUR DEVICE
1.
To allow the device to connect, go to Setup > GPS Configuration > Client Configuration.
2.
Check TCP/UDP Client.
3.
From the Protocol drop-down list, select the protocol of the client (TCP or UDP).
4.
In the Remote Host field, type the IP address of the remote host.
5.
In the Port, field type the port number of the remote host.
6.
If your remote host requests a password, type that password in the Password field. The password is sent
to the server in response.
7.
Click Submit.
8.
To save your changes, click Save and Restart.
Configuring NMEA Sentences
To configure the time interval, additional prefix or ID information, and which NMEA sentences that can be sent:
1.
Go to Setup > GPS Configuration > NMEA Configuration and in the Interval field, type the amount of
time, in seconds, that passes before the NMEA information is sent. The default is 10 seconds. The range is
1 to 255 seconds.
2.
You can further identify the router, also called a remote asset, that is collecting and sending the GPS
information. To do so:
Add ID: The ID is an unique remote asset identification string. The ID string can be any length up to 20
characters. The & and $ are invalid characters. The ID must follow the standard NMEA sentence structure.
Refer to the Universal IP AT Commands Reference Guide for sentence structure.
To add more information to the beginning of the ID, in the Add ID Prefix field, type the information.
3.
You can select which NMEA sentence types you want to send. Check any combination of the available
options: GGA, GSA, GSV, GLL, RMC, and VTG.
Configuring the Serial Port
To configure the serial terminal connected to the RS-232 connector on the router:
1.
Go to Setup > Serial IP Configuration > Serial Port Settings, check Enabled.
2.
From the Baud Rate drop-down list, select the baud-rate at which the serial terminal communicates. The
default is 115200.
3.
From the Flow Control drop-down list, select the flow control for the serial port. The options are NONE or
RTS-CTS. The default is NONE.
4.
From the Parity drop-down list, select the parity for the serial port. The options are NONE, EVEN, or ODD.
The default is NONE.
5.
To use the Modbus protocol as the protocol the serial devices use to communicate, check Modbus
Gateway to the right of Enabled. NOTE: You may have the TCP connection encrypted with TLS. Make sure
to check Protocol under IP Pipe and select SSL/TLS.
6.
From the Data Bits drop-down list, select the data bits for the serial port. Data bit options are 7 or 8. The
default is 8.
7.
From the Stop Bits drop-down list, select the stop bits for the serial port. The options are 1 or 2. The
default is 1.
8.
Click Submit.
9.
To save your changes, click Save and Restart.