Emerson SI-DeviceNet User Manual page 48

Table of Contents

Advertisement

Bit
Parameter
6
Pr 10.007
7
Pr 10.008
8
Pr 10.009
9
Pr 10.010
10
Pr 10.011
11
Pr 10.012
12
Pr 10.013
13
Pr 10.014
14
Pr 10.015
15
(Not Used)
48
Above set speed
Only set if the drive is running at above set speed. Refer to
Pr 03.006, Pr 03.007 and Pr 03.009 in the drive documentation for
more details.
Load reached
Indicates that the modulus of the active current is greater or equal
to the rated active current, as defined in menu 4. Refer to the drive
documentation for more details.
In current limit
Indicates that the current limits are active.
Regenerating
Indicates that power is being transferred from the motor to the
drive.
Regen mode: Indicates that power is being transferred from the
drive to the supply.
Dynamic brake active
Indicates that the braking IGBT is active. If the IGBT becomes
active, this parameter will remain on for at least one second.
Dynamic brake alarm
Dynamic brake alarm is set when the braking IGBT is active, and
the braking energy accumulator is greater than 75 %.
Reverse direction commanded
Direction commanded is set to 1 if the Pre-ramp speed reference
(Pr 01.003) is negative and reset to 0 if the Pre-ramp speed
reference is zero or positive.
Reverse direction running
A 0 indicates forward direction and a 1 indicates reverse direction.
The source of this bit is Pr 02.001 for open loop mode and
Pr 03.002 for RFC-A and RFC-S modes.
Supply loss
Supply loss indicates that the drive has detected a supply loss from
the level of the DC bus voltage. This parameter can only become
active if supply loss ride through or supply loss stop modes are
selected.
In regen mode, supply loss is the inverse of Pr 03.007.
Reserved
Description
SI-DeviceNet User Guide
Issue Number: 2