3.6

SCL/SCM Control Wiring Diagrams

3.6.1

SCL/SCM Terminal Strip

Shown below is the control terminal strip, along with a brief description of the function of each
terminal. The following wiring diagram examples provide a quick reference to wire the drive for the
most common configurations.
1
2
5
+
-
Maintained
RUN/STOP
Contact
SCL/SCM Terminal Strip
NOTE
The function of terminals TB-13A, 13B, 13E and the Form A relay at terminals 16
and 17 are dependent on the programming of certain parameters.
Refer to Section 4.4 Description of Parameters.
The digital inputs (terminals 1, 13A, 13B, and 13E) are active-high. They can
be activated using terminal 11 (which is +12 VDC) as shown in the following
diagrams, or by using an external voltage source with a range of +12 VDC to +28
VDC (+ 10%).
Lenze 13466147 EDBSM01 v19 EN
6
11
13A
13B
Installation
13E
25
+
FORM A RELAY
17
16
3
21