Ethernet; Infra Tab - Lightware MMX8x8-HDMI-4K-A User Manual

Multiport matrix switcher
Hide thumbs Also See for MMX8x8-HDMI-4K-A:
Table of Contents

Advertisement

 
5. Software Control – Lightware Device Controller
Port name
Baud rate: 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200;
Data bits: 8 or 9;
Parity: None, Odd, or Even;
Stop bits: 1, 1.5, or 2;
Command injection port number;
Control protocol: LW2 or LW3;
Message sending
Reloading factory defaults (see factory default settings in the Factory Default Settings section).
5.9.2. Ethernet
CPU (P1) and Control Ethernet (P2) ports are displayed on this tab.
In MMx8x4-HT420M model there are more ports as it is seen on the picture below:
Ethernet Link TPS Out (P3)
Ethernet Link TPS In (P4)
TPS IN 1-4 (P5-8)
TPS OUT 1-2 (P9-P10)
The Ethernet ports display the status of the Ethernet, speed, and the duplexity of the connection.
The following settings are also available:
Port name
Enable / disable the port (for loop protection);
Reloading factory defaults (see factory default settings in the Factory Default Settings section).
ATTENTION! If the Ethernet port is set to disabled, this may break the connection with the device.
INFO: CPU Ethernet port can not be disabled.
Ethernet tab in Control menu
MMX8x4-HT series – User's Manual
5.9.3. Infra tab
ATTENTION! The device has no built-in Infrared transmitter. For the complete usage attach an IR emitter
unit to the IR OUT connector.
All the infra ports are transmitters and they are able to forward the Infra message, which comes from the
Control Ethernet port (the operation mode is always Command Injection).
The following settings are also available:
Port name
Enable / disable the port;
Port number
Enable / disable command injection
Reloading factory defaults (see factory default settings in the
Infra tab in Control menu
Factory Default Settings
47
section).