Elcometer FD700DL+ Operating Instructions Manual page 48

Corrosion and flaw gauge
Table of Contents

Advertisement

M
EMORY CAPACITY
You can create and save as many data files as required up to the maximum capacity of the gauge
memory (32 Mbit). If you try to create a new file which exceeds the memory capacity, the gauge will
display an error message. Saved data must be deleted in order to make the space available..
Save Graphics Option
On
Off
24.2 CREATING A NEW DATA LOGGER FILE - GRID FORMAT
To create a GRID log data file:
1. Select MENU/DATA/NEW
2. Use (LEFT) or (RIGHT) keys to choose between grid and sequential log
types
3. Press ENTER to continue
4. Fill in a name and a note (if desired) for your data logger file
5. Select the size of the grid. Grid positions are denoted by a number and a
letter, where the letter is the column and the number is the row.
Use TOP LEFT and LOWER RIGHT to define the size of the grid. For
example, a with the TOP LEFT set to A001 and LOWER RIGHT C003 would
produce a 3x3 grid
The grid can have a maximum of 52 columns and 999 rows
6. Set the Auto Increment direction. This option allows you to select which
direction the cursor moves after a reading is stored in terms of compass
points. For example NORTH would move the cursor up a row, and WEST
would move a column left.
7. Choose whether to activate SAVE GRAPHICS or not (snapshot of the A OR
B scan on screen).
8. Finally create the log by scrolling to CREATE LOG, pressing ENTER and
then OK to confirm.
The measurement grid is now displayed along with the grid name on screen.
47
Memory Capacity
(readings)
16 000 +
210 000 +