Ambient Process; Nozzle Cleaning; Troubleshooting - lancer Spartan Operation Manual

Table of Contents

Advertisement

3.2
CLEANING AND SANITIZING SOLUTIONS (CONTINUED)
INTEGRITY OF THE PLASTIC FINISH: While caring for your Spartan, please note that there may
be some cleaners that may compromise the integrity of the plastic finish. Most common cleaners
such as Windex, Dawn, 409, etc. pose no threat to the plastic finish of the unit. However, certain
cleaners with high levels of acetic acid, ethylbenzene, isopropylamine, etc., at certain temperatures,
could cause aesthetic damage. Please refer to this webpage,
chemical-resistance-of-lldpe, to make sure that you are properly caring for your unit.
3.3

AMBIENT PROCESS

The ambient process is the most common method for cleaning and sanitizing dispenser equipment.
A. Prepare the Cleaning Solution,referred to in Section 3.2.
B. Fill lines at pump inlet with Cleaning Solution ( Section 2.2). The solution should be prepared in
accordance with the manufacturer's recommendations. Make sure the lines are completely filled
and allow to stand for at least ten (10) minutes.
C. Flush the detergent solution from the lines with clean water.
D. Prepare the Sanitizing Solution, referred to in Section 3.2.
E. Fill the lines with Sanitizing Solution. Make sure that lines are completely filled and allow to
stand for ten (10) minutes.
F. Draw drinks to refill lines and flush solution from the dispenser.
G. Taste the beverage to verify that there is no off taste. If off-taste is found, flush the syrup
system again.
CAUTION
NOT USE A FRESH WATER RINSE. THIS IS A NSF REQUIREMENT. RESIDUAL SANITIZING SOLUTION LEFT IN THE
SYSTEM CREATES A HEALTH HAZARD.
!
PRECAUCIÓN
ELIMINAR EL SABOR QUE QUEDA. NO ENJUAGUE CON AGUA FRESCA. ÉSTA ES UNA EXIGENCIA DE NSF. SI
QUEDA SOLUCIÓN DE ESTERILIZACIÓN EN EL SISTEMA, GENERA UN PELIGRO PARA LA SALUD.
ATTENTION
SEPTIQUE.EN CAS DE APRÈS-GOÛT, NE PURGER AVEC LE PRODUIT FINAL UNE EXIGENCE NSF.
3.4

NOZZLE CLEANING

A. Disconnect power so not to activate the valve while cleaning. Remove nozzle and diffuser. Wash
these parts in cleaning solution, then immerse them in a bath of sanitizing solution for
15 minutes.
B. Wearing sanitary gloves, remove, drain and air dry the nozzle and diffuser.
C. Wearing sanitary gloves, replace diffuser and twist nozzle into place.
D. Connect power.

4. TROUBLESHOOTING

TROUBLE
4.1 Water leakage around nozzle.
4.2 Leakae between upper and lower
valve bodies.
4.3 Miscellanease leakage.
FOLLOWING SANITIZATION, RINSE WITH END-USE PRODUCT UNTIL THERE IS NO AFTERTASTE. DO
DESPUÉS DE LA ESTERILIZACIÓN, ENJUAGUE CON EL PRODUCTO FINAL HASTA QUE
DÉFENSE DE RINCER L'OUTIL À L'EAU FRAICHE IMMÉDIATEMENT APRÈS UN TRAITEMENT
A. Damaged or improperly installed o-ring
above diffuser.
A. Gap between upper and lower valve
bodies.
B. Worn or damaged paddle arm
assemblies.
C. Cracked valve bodies
A. Gap between parts.
B. Damaged or improperly installed
o-rings.
http://www.vita.com.cy/index.php/
CAUSE
16
REMEDY
A. if damaged, replace. If imporoperly
installed, adjust.
A. Tighten all six (6) retaining screws.
B. Replace paddle arm assemblies.
C. Replace Valve Body.
A. Tighten appropriate retaining screws
B. Replace or adjust appropriate o-rings