Connecting To Co2 Supply; Connecting To Bag-In-Box (Bib) Syrup Supply To Remote Syrup Pumps; Purging The Carbonation System; Purging The Water And Syrup Systems - lancer Spartan Operation Manual

Table of Contents

Advertisement

1.8
CONNECTING THE CO2 SUPPLY
A. Connect high pressure CO2 regulator assembly to CO2 cylinder or bulk system. Use a new CO2
tank washer if regulator does not have built-in o-ring seal.
B. Place CO2 cylinder in service location under counter, etc., and secure it with a safety chain.
C. Install secondary CO2 regulator if the bulk system is utilized.
D. Route gas line through hole in counter. Connect CO2 to designated inlet behind the dispenser.
E. Leave 12 inches (305 mm) of extra tubing length below the counter for servicing and moving the
dispenser.
WARNING
DO NOT TURN ON THE CO2 SUPPLY AT THIS TIME.
5
ADVERTENCIA
AVERTISSEMENT
1.9

CONNECTING TO BAG-IN-BOX (BIB) SYRUP SUPPLY TO REMOTE SYRUP PUMPS

A. To connect CO2 regulator assembly to the CO2 cylinder, see Section 1.9, Steps A - C.
B. Place the remote BIB syrup supply and pumps in a convenient location.
C. Attach the syrup supply tubes to the dispenser's syrup inlet fittings using an Oetiker clamp for
each syrup flavor.
D. Route the syrup supply tubes to the remote syrup pumps.
E. Complete installation of the remote syrup pump system following the manufacturer's
instructions.

1.10 PURGING THE CARBONATION SYSTEM

A. Turn on water source. Lift the black lever on the top of the carbonator tank relief valve until
water flows from the holes in the relief valve. Then release the relief valve.
B. Reconnect the power supply to the carbonator pump.
C. Back off on the CO2 regulator pressure adjusting screw all the way. Open the CO2 cylinder
handle slowly. Turn the CO2 pressure regulator up slowly to 75 PSIG (0.510 MPA).
D. Press and hold each valve lever until water is flowing steadily from each valve.
E. Check all of the unit's water, syrup, and CO2 connections for leaks and repair if necessary.
NOTE: Tank Method Only - to check for CO2 leaks, close the valve on the CO2 cylinder and
observe if the pressure to the system drops with the cylinder valve closed for five (5) minutes.
Open the cylinder valve after check.
F. Assemble the unit's bonnet, splash plate, and rear guard.
NOTE: Ensure a minimum of 5 gallons of water is flushed through each valve prior to use.

1.11 PURGING THE WATER AND SYRUP SYSTEMS

A. Set the adjustable back blocks to deliver plain water
B. Open a dispensing valve until water and syrup are flowing steadily from the valve.
C. Repeat procedure "A" for each valve.
D. Check all of the unit's syrup and water connections for leaks and repair if necessary.
E. Replace the unit's bonnet, splash plate and cup rest
NO CONECTE TODAVÍA LA ALIMENTACIÓN DE CO2.
N'OUVREZ PAS L'ALIMENTATION EN CO2 À CE MOMENT.