Dispenser Disposal - lancer Spartan Operation Manual

Table of Contents

Advertisement

TROUBLE
4.28 BIB pump fails to restart when
dispensing valve is closed.
4.29 No product out light.
4.30
Low or no carbonation.

5. DISPENSER DISPOSAL

 
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was pur
chased. Comply with local regulations regarding disposal of the refrigerant and insulation.
CAUSE
A. Leak in discharge line or fittings.
B. Empty BIB.
C. Air leak on inlet line or bag connector.
A. Burned-out lamp
B. Faulty wiring or pressure switch in
product line.
A. Low or no CO
.
2
B. Excessive water pressure.
C.Worn or defective carbonator pump.
D.PCB malfunctioning.
24
REMEDY
A. Repair or replace discharge
B. Replace BIB.
C. Repair or replace.
A. Replace lamp.
B. Repair or replace.
supply. Adjust CO
A. Check CO
2
pressure to 70 PSI (0.483 MPA).
B. Water regulator should be set at 50
PSI (0.345 MPA)
C. Replace carbonator pump.
D. See Section 6.
2