1. INSTALLATION

1.1

UNPACKING

A. Cut band and remove.
B. Remove accessory kit and loose parts.
C. Remove top board, corner inserts, and lift outer carton to remove, if included.
D. Inspect unit for concealed damage. If evident, notify delivering carrier and file a claim against
same.
E. Remove plywood shipping base from unit by moving unit so that one side is off the counter top
or table allowing access to screws on the bottom of the plywood shipping base.
NOTE: If unit is to be transported, it is advisable to leave the unit secured to the plywood base.
F. If leg kit has been provided, assemble legs to unit by tilting unit. DO NOT LAY UNIT ON ITS
SIDE OR BACK.
1.2

UNPACKING INSTALLATION KITS

A. Inspect kits for concealed damage and if evident, notify delivering carrier and file a claim
against same.
B. Each kit contains a list of the parts and a drawing showing the proper assembly of the parts.
1.3

SELECTING A COUNTER LOCATION

A. Select a location close to a properly grounded electrical outlet and water supply that meet the
requirements as shown in the SPECIFICATIONS section.
WARNING
FAILURE TO MAINTAIN SPECIFIED CLEARANCE WILL CAUSE THE COMPRESSOR TO OVERHEAT
AND WILL RESULT IN COMPRESSOR FAILURE.
!
ADVERTENCIA
FALLAR.
AVERTISSEMENT
COMPRESSEUR ET AURA COMME CONSÉQUENCE UNE DÉFAILLANCE DU COMPRESSEUR.
B. Condenser air is drawn in from the front and side vents located on the bonnet, and discharged
out the rear of the bonnet. A minimum of eight (8) inches (203 mm) clearance must be main
tained over the top of the unit and a minimum 4 inches behind the unit to provide for proper air
flow and air circulation.
1.4

LEVELING THE DISPENSER

In order to facilitate proper dispenser drainage and carbonation, ensure that the dispenser is level,
front to back and side to side. Place a level on the top of the rear edge of the dispenser. The bubble
must settle between the level lines. Repeat this procedure for the remaining three sides. Level
unit if necessary. For optimum performance place the unit at a 0 degree tilt. The maximum tilt is 5
degrees.
1.5
FILLING UNIT WITH WATER
CAUTION
THE WATER BATH COMPARTMENT MUST BE FILLED WITH WATER BEFORE PLUGGING IN THE UNIT,
OTHERWISE THE COMPRESSOR DECK AND CONDENSOR FAN MAY NOT OPERATE PROPERLY
!
PRECAUCIÓN
LA UNIDAD PUES, DE LO CONTARIO, LA PLATAFORMA DEL COMPRESOR Y EL VENTILADOR DEL
CONDENSADOR NO FUNCIONARÍAN CORRECTAMENTE.
ATTENTION
LE COMPARTIMENT DE BAIN-MARIE DOIT ÊTRE REMPLI AVEC DE L'EAU AVANT DE BRANCHER
L'APPAREIL, SINON LA PLATEFORME DU COMPRESSEUR ET LE VENTILATEUR DU CON- DENSATEUR PEUVENT
NE PAS FONCTIONNER CORRECTEMENT.
A. Remove splash plate and drip tray. Assemble drain tube on drip tray drain elbow.
B. Remove the bonnet from the unit by removing the two side screws, top screw, and lifting
upward.
C. Locate the opening in the compressor deck. A yellow cap will identify opening. Remove the cap.
D. Using a funnel or tube, fill the water bath compartment, with water until it flows out of the over
flow tube into the drip tray.
SI NO DEJA EL ESPACIO LIBRE ESPECIFICADO EL COMPRESOR PUEDE RECALENTAR Y
LE FAIT DE NE PAS MAINTENIR LE DÉGAGEMENT SPÉCIFIÉ FERA SURCHAUFFER LE
EL COMPARTIMIENTO DE BAÑO DE AGUA DEBA ESTAR LLENO DE AGUA ANTES DE ENCHUFAR